IBM Mainframe Forum Index
 
Log In
 
IBM Mainframe Forum Index Mainframe: Search IBM Mainframe Forum: FAQ Register
 

Need a command to issue a MACRO


IBM Mainframe Forums -> TSO/ISPF
Post new topic   Reply to topic
View previous topic :: View next topic  
Author Message
tecnokrat
Warnings : 1

Active User


Joined: 22 May 2009
Posts: 160
Location: Bangalore

PostPosted: Fri Mar 09, 2012 11:16 am
Reply with quote

i need to issue a command once the ISPEXEC VIEW statement is issued on an element.

The command is to be emebedded in the REXX program and that should be done immediately after the VIEW is done.

Please can you help me with any statement of the ISPEXEC to issue a command on the command prompt as it is a MACRO.
Back to top
View user's profile Send private message
Nic Clouston

Global Moderator


Joined: 10 May 2007
Posts: 2454
Location: Hampshire, UK

PostPosted: Fri Mar 09, 2012 1:18 pm
Reply with quote

Why not just issue it manually? Why use a program to display you view panel? Why not look up the syntax of edit/view?
Back to top
View user's profile Send private message
tecnokrat
Warnings : 1

Active User


Joined: 22 May 2009
Posts: 160
Location: Bangalore

PostPosted: Fri Mar 09, 2012 2:39 pm
Reply with quote

Actually i have two different sets one is to view and then again issue a command to get the next.

But now that it can be housed in a single one I'm thinking of to issue the macro at a go.

Say as i issue a view command its only vies the required DS but only after the PF3 the next Call to my macro is initiated.

instead as the view command is issued simultaneously the Macro with the required parameterd are to be issued at one go.
Back to top
View user's profile Send private message
enrico-sorichetti

Superior Member


Joined: 14 Mar 2007
Posts: 10903
Location: italy

PostPosted: Fri Mar 09, 2012 2:52 pm
Reply with quote

why not look at the manual Yourself for the syntax and the parameters of the
VIEW command when issued thru Address ISPEXEC

here is a link to an ISPF bookshelf
publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/Shelves/ISPZPM70
old but more than enough for Your needs
it would have enlightened You and saved the wait for a forum answer
Back to top
View user's profile Send private message
View previous topic : : View next topic  
Post new topic   Reply to topic All times are GMT + 6 Hours
Forum Index -> TSO/ISPF

 


Similar Topics
Topic Forum Replies
No new posts USAGE parameter of RACDCERT CONNECT c... All Other Mainframe Topics 2
No new posts CICS-Db2 connection issue CICS 1
No new posts creat new line command in front of Me... TSO/ISPF 4
No new posts SAVEPOINT ON ROLLBACK RETAIN CURSORS ... DB2 1
No new posts c all command JCL & VSAM 11
Search our Forums:


Back to Top