View previous topic :: View next topic
|
Author |
Message |
vidhyag
New User
Joined: 11 Mar 2009 Posts: 23 Location: india
|
|
|
|
hi,
I am getting following error after installing TWS.
EQQZ066W OPC HAS NOT BEEN ABLE TO DETERMINE THE JES TYPE. JES3 IS ASSUMED.
EQQZ073I OPC HAS RECOGNIZED THAT THIS IS A JES3 SYSTEM WITH
Actually i need JES2 system.I added EXIT7 and EXIT51 modules also.But still facing same error.Any one suggest on this |
|
Back to top |
|
|
nevilh
Active User
Joined: 01 Sep 2006 Posts: 262
|
|
|
|
Quote: |
Actually i need JES2 system.I added EXIT7 |
Did you also define the exit as active to Jes |
|
Back to top |
|
|
vidhyag
New User
Joined: 11 Mar 2009 Posts: 23 Location: india
|
|
|
|
Hi,
I found that it is disable with the help of command $t exit(7).Kindly tell me,how to enable it
Thanks, |
|
Back to top |
|
|
nevilh
Active User
Joined: 01 Sep 2006 Posts: 262
|
|
|
|
$Texit(7),status=enbled |
|
Back to top |
|
|
vidhyag
New User
Joined: 11 Mar 2009 Posts: 23 Location: india
|
|
|
|
Hi,
It is working now.Thank for timely help |
|
Back to top |
|
|
|