EnjoyMF

New User


Joined: 27 May 2005
Posts: 88

PostPosted: Thu Jan 19, 2006 6:22 pm
Reply with quote

Hi guys


I always get S522 error as time out error

Can some one tell me when we get S522 error



Regards
Prasad
Back to top
View user's profile Send private message
MGIndaco

Active User


Joined: 10 Mar 2005
Posts: 432
Location: Milan, Italy

PostPosted: Thu Jan 19, 2006 6:26 pm
Reply with quote

Try to install Abend Assist v1.0 icon_biggrin.gif
Reason:
Quote:
All of the tasks in a job step were in an SVC wait state for the time specified in the JWT parameter in the SMFPRMxx parmlib member. The event control block (ECB) specified in the wait request was never posted. This could be the result of waiting on the wrong ECB or not posting the correct ECB

User Response:
Quote:
Correct any errors and execute the job step again. If no errors are found and the wait is expected for that particular job step, specify TIME=NOLIMIT in the EXEC statement to bypass all job step timing.


Hope in this. icon_wink.gif
Back to top
View user's profile Send private message
Bitneuker

CICS Moderator


Joined: 07 Nov 2005
Posts: 1104
Location: The Netherlands at Hole 19

PostPosted: Thu Jan 19, 2006 8:09 pm
Reply with quote

Hi Mainframe enjoyer,

IMHO S522 stands for too long waiting for mounting a required device like tape or disk.

Cheers,
Back to top
View user's profile Send private message
mcmillan

Site Admin


Joined: 18 May 2003
Posts: 1210
Location: India

PostPosted: Thu Jan 19, 2006 9:52 pm
Reply with quote

Check this Post:

www.ibmmainframes.com/viewtopic.php?t=8295
Back to top
View user's profile Send private message
Bitneuker

CICS Moderator


Joined: 07 Nov 2005
Posts: 1104
Location: The Netherlands at Hole 19

PostPosted: Thu Jan 19, 2006 9:58 pm
Reply with quote

mcmillan,

You're right: just tried to give an example of a possible reason this SVC was waiting. icon_wink.gif

Cheers,
Back to top
View user's profile Send private message
View previous topic :: :: View next topic  
Post new topic   Reply to topic View Bookmarks
All times are GMT + 6 Hours
Forum Index -> ABENDS & Debugging

 


Similar Topics
Topic Forum Replies
No new posts Error to read log with rexx CLIST & REXX 11
No new posts Error when install DB2 DB2 2
No new posts CLIST - Virtual storage allocation error CLIST & REXX 5
No new posts Error while running web tool kit REXX... CLIST & REXX 5
No new posts Getting Error while trying to establi... DB2 3
Search our Forums:

Back to Top