ravichella

New User


Joined: 19 Jan 2006
Posts: 1

PostPosted: Thu Jan 19, 2006 11:29 am
Reply with quote

Hi All,

How is that we could get a S3222 despite time being maximum?
Back to top
View user's profile Send private message
Rupesh.Kothari

Member of the Month


Joined: 27 Apr 2005
Posts: 463

PostPosted: Thu Jan 19, 2006 12:12 pm
Reply with quote

HI,


Quote:
How is that we could get a S3222 despite time being maximum???


I didn't get you could you please elaborate your proble. I never seen S3222 abend in my Shop.

Regards
Rupesh
Back to top
View user's profile Send private message
senthils

Active User


Joined: 15 Nov 2005
Posts: 117
Location: Chennai, India

PostPosted: Thu Jan 19, 2006 12:33 pm
Reply with quote

I think he means S322. It can happen if the the job class is wrongly given.
For example assume for CLASS A the shop has set a time limit of 10 Sec. If your job runs for more than 10 Sec then you will get S322. This can happen even though you have specified more amount of time in TIME parameter.
Back to top
View user's profile Send private message
Rupesh.Kothari

Member of the Month


Joined: 27 Apr 2005
Posts: 463

PostPosted: Thu Jan 19, 2006 1:16 pm
Reply with quote

HI,

If It is S322
Then reason for this will be

The system took a longer time to run a job, job step, or procedure than the time specified in one of The following: The TIME parameter of the EXEC or JOB statement The standard time limit specified in the job entry subsystem For a started task under the master subsystem, the TIME parameter was not specified on the PROC statement of the catalogued procedure, and the PPT entry did not indicate a system task

To overcome this increase the Time parameter or use NOLIMIT.

Hope this helps

Regards
Rupesh
Back to top
View user's profile Send private message
saithvis2

New User


Joined: 23 Dec 2005
Posts: 61
Location: Providence , US

PostPosted: Thu Jan 19, 2006 2:52 pm
Reply with quote

Hi,

If in case there is still problem persisting with nolimit with the specified Class then better use a different class , like in our shop if class X gives a S322 abend along with time=1440 paramter we shift our class to L and though the job takes longer time to finish , it passes of successfully , so better change the class if no limit doesnt work.

Correct me if i am wrong .

Regards
Vishal
Back to top
View user's profile Send private message
priyesh.agrawal

Senior Member


Joined: 28 Mar 2005
Posts: 1448
Location: Chicago, IL

PostPosted: Thu Jan 19, 2006 5:06 pm
Reply with quote

It is always suggestable to look out the step involved in abend for S322, if maximum time is also not working.

Check for a never ending loop or the step program to get the reason behind the long execution time.

Regards,

Priyesh.
Back to top
View user's profile Send private message
View previous topic :: :: View next topic  
Post new topic   Reply to topic View Bookmarks
All times are GMT + 6 Hours
Forum Index -> ABENDS & Debugging

 


Similar Topics
Topic Forum Replies
No new posts To get the the current time DFSORT/ICETOOL 13
No new posts RC query -Time column CA Products 3
No new posts C Compile time time stamps Java & MQSeries 10
No new posts Parallelization in CICS to reduce res... CICS 4
No new posts Insert system time/date (timestamp) u... DFSORT/ICETOOL 5
Search our Forums:

Back to Top