Facing PROG753 error in few systems only


IBM Mainframe Forums -> CICS
Post new topic   Reply to topic
View previous topic :: View next topic  
Author Message
ac288009

New User


Joined: 19 Nov 2013
Posts: 2
Location: switzerland

PostPosted: Wed Nov 20, 2013 3:43 pm
Reply with quote

Hi, Online transaction is abending(Struck) with PROG753 error in Z/VSE system.only few users were facing this issue, and for few users it is working fine. so i want to know whether it is the problem with code or it is problem with settings in EXTRA emulator

Thanks,
Ashok
Back to top
View user's profile Send private message
Raghu navaikulam

Active User


Joined: 27 Sep 2008
Posts: 193
Location: chennai

PostPosted: Wed Nov 20, 2013 4:10 pm
Reply with quote

Hi Ashok,

I am new to VSE. In Z/os, I suspect an initialization problem. If a field is not initialized properly, the result will be unpredictable. Check the fields at the time of ABEND.

Regards
Raghunathan
Back to top
View user's profile Send private message
enrico-sorichetti

Superior Member


Joined: 14 Mar 2007
Posts: 10873
Location: italy

PostPosted: Wed Nov 20, 2013 4:17 pm
Reply with quote

not a CICS problem, really, PROGxxx are hardware related errors,
if it happens only on some emulated terminals start looking at differences in the configuration of the emulation.
Back to top
View user's profile Send private message
ac288009

New User


Joined: 19 Nov 2013
Posts: 2
Location: switzerland

PostPosted: Wed Nov 20, 2013 4:52 pm
Reply with quote

Raghu navaikulam wrote:
Hi Ashok,

I am new to VSE. In Z/os, I suspect an initialization problem. If a field is not initialized properly, the result will be unpredictable. Check the fields at the time of ABEND.

Regards
Raghunathan


Thanks for quick reply.. But the same code is working fine in few systems.. so i hope it is not problem with code...
Back to top
View user's profile Send private message
Robert Sample

Global Moderator


Joined: 06 Jun 2008
Posts: 8697
Location: Dubuque, Iowa, USA

PostPosted: Wed Nov 20, 2013 5:35 pm
Reply with quote

My Goolge search of PROG753 indicates that LE initialization differences between the systems could cause your problem.
Back to top
View user's profile Send private message
Pepero2k3

New User


Joined: 07 Sep 2008
Posts: 7
Location: Iran

PostPosted: Wed Nov 20, 2013 10:08 pm
Reply with quote

In Z/OS The problem is sending the non printable characters in BMS. There is an 'Storage clear' attribute in the definition of the transaction. When turning on this switch the allocated storage is cleared at first.
Back to top
View user's profile Send private message
Peter cobolskolan

Active User


Joined: 06 Feb 2012
Posts: 104
Location: Sweden

PostPosted: Thu Nov 21, 2013 7:40 pm
Reply with quote

This is probably a programming error. Ensure the Working-Storage used for the output-map is Low-Value before its populated with some data and sent via EXEC CICS SEND MAP('TheMap'), like Move Low-Value to TheMapO.
The problem can occur randomly, as the content of the unitialized Working-Storage/Maparea varies from time to time.
Back to top
View user's profile Send private message
View previous topic :: :: View next topic  
Post new topic   Reply to topic View Bookmarks
All times are GMT + 6 Hours
Forum Index -> CICS

 


Similar Topics
Topic Forum Replies
No new posts Error to read log with rexx CLIST & REXX 11