View previous topic :: View next topic
|
Author |
Message |
gaurav.rajvanshi
New User
Joined: 08 Jul 2010 Posts: 23 Location: Mainframe World
|
|
|
|
What is Checkin Service Error in Changeman.
I try staging components to a changeman package, but staging fails due to 'Checkin Service Error'.
Is this because two people are trying to access and stage the components in the same package at the same time. If yes, is there a way to overcome this.
Thanks |
|
Back to top |
|
|
mistah kurtz
Active User
Joined: 28 Jan 2012 Posts: 316 Location: Room: TREE(3). Hilbert's Hotel
|
|
|
|
Can you check if your component is LOCKed? If a component is in locked status you need to Unlock Component(line command: UC) to allow for Checkout/Stage. |
|
Back to top |
|
|
Anuj Dhawan
Superior Member
Joined: 22 Apr 2006 Posts: 6250 Location: Mumbai, India
|
|
|
|
It's been a while when I worked with Change-Man but next time when you get this error, press PF1 key and it'll give you a rather long explanation about the error.
Second, if your shop is licensed to use Serena Change-Man, all this is explained in manuals - try to get them or use online help from Change-Man menu options. |
|
Back to top |
|
|
gaurav.rajvanshi
New User
Joined: 08 Jul 2010 Posts: 23 Location: Mainframe World
|
|
|
|
Found the problem...
SPACE Related issue. Changeman library is used to its max. Ran the Compress job and now it is fine...
Thanks for your replies... |
|
Back to top |
|
|
Anuj Dhawan
Superior Member
Joined: 22 Apr 2006 Posts: 6250 Location: Mumbai, India
|
|
|
|
Thanks for posting what worked for you, appreciate that. |
|
Back to top |
|
|
|