IBM Mainframe Forum Index
 
Log In
 
IBM Mainframe Forum Index Mainframe: Search IBM Mainframe Forum: FAQ Register
 

SCLM build processor error


IBM Mainframe Forums -> IBM Tools
Post new topic   Reply to topic
View previous topic :: View next topic  
Author Message
as4578

New User


Joined: 24 Jun 2010
Posts: 12
Location: China

PostPosted: Tue Dec 14, 2010 11:24 am
Reply with quote

When I built the PL/I with the processor,there is a error

*********************************************
FLM49000 - INVOKING BUILD PROCESSOR
FLM09002 - THE BUILD REPORT WILL APPEAR IN xxxxxx.BUILD.REPORT39
FLM09004 - THE BUILD MESSAGES WILL APPEAR IN xxxxxx.BUILD.MSGS39
FLM09006 - THE BUILD LISTING WILL APPEAR IN xxxxxx.LIST39

IEW4000I FETCH FOR MODULE IBM3TBY FROM DDNAME SLXT54Z0 FAILED BECAUSE INSUFFIC
IENT STORAGE WAS AVAILABLE.
CSV031I LIBRARY ACCESS FAILED FOR MODULE IBM3TBY , RETURN CODE 24, REASON CODE
26080021, DDNAME SLXT54Z0
Unable to load phase: IBM3TBY
FLM09008 - RETURN CODE = 8
**********************************************************

I know nothing about what has happened.

I seems there is no storage definiation in the SCLM translators MACRO.

Is there somebody has the same problem?

Can somebody help me? Thanks a lot.
Back to top
View user's profile Send private message
enrico-sorichetti

Superior Member


Joined: 14 Mar 2007
Posts: 10873
Location: italy

PostPosted: Tue Dec 14, 2010 12:21 pm
Reply with quote

did You care to look at the IBM messages and codes manual
for the IEW4000I message explanation and related actions ?

You can start from
www-03.ibm.com/systems/z/os/zos/bkserv/index.html

use the LookAT facility to search for messages
www-03.ibm.com/systems/z/os/zos/bkserv/lookat/

an happily proceed on

the only people who can help You really are those who setup the SCLM environment
Back to top
View user's profile Send private message
as4578

New User


Joined: 24 Jun 2010
Posts: 12
Location: China

PostPosted: Tue Dec 14, 2010 12:41 pm
Reply with quote

The 'message and code' always ask me to contact with the system Adm.
But I am the ADM icon_smile.gif.
I have no experienc with SCLM.


*************************
System action:
An abend will occur unless the program was loaded by a LOAD macro with the ERRET option specified.

User response:
Rerun the job with a larger region size specified.

**********************************************************

How can I enlarge the size in SCLM translators with the macro.
FLMALLOC?
FLMTRNSL ?

which Parameter is about the region size?


By the way, thank you all the same,Enrico.
Back to top
View user's profile Send private message
enrico-sorichetti

Superior Member


Joined: 14 Mar 2007
Posts: 10873
Location: italy

PostPosted: Tue Dec 14, 2010 3:41 pm
Reply with quote

I am not on the mainframe now...
look at the JES output and see if the region parameter was specified anywhere
if there is no parameter on the each exec You can specify one on the JOB card
Back to top
View user's profile Send private message
as4578

New User


Joined: 24 Jun 2010
Posts: 12
Location: China

PostPosted: Wed Dec 15, 2010 7:00 am
Reply with quote

Is there anybody is using SCLM now ?
Back to top
View user's profile Send private message
dick scherrer

Moderator Emeritus


Joined: 23 Nov 2006
Posts: 19244
Location: Inside the Matrix

PostPosted: Wed Dec 15, 2010 8:47 am
Reply with quote

Hello,

We have very few sclm topics (around 10 this year).

Suggest you open an issue with product support.
Back to top
View user's profile Send private message
as4578

New User


Joined: 24 Jun 2010
Posts: 12
Location: China

PostPosted: Wed Dec 15, 2010 8:50 am
Reply with quote

Is there anybody know the EMAIL of SCLM product support?
Back to top
View user's profile Send private message
dick scherrer

Moderator Emeritus


Joined: 23 Nov 2006
Posts: 19244
Location: Inside the Matrix

PostPosted: Wed Dec 15, 2010 8:59 am
Reply with quote

Hello,

You might start here:
www-01.ibm.com/software/awdtools/sclmsuite/
Back to top
View user's profile Send private message
enrico-sorichetti

Superior Member


Joined: 14 Mar 2007
Posts: 10873
Location: italy

PostPosted: Wed Dec 15, 2010 9:44 am
Reply with quote

my
Quote:
I am not on the mainframe now...

Your
Quote:
Is there anybody is using SCLM now ?

Your
Quote:
Is there anybody know the EMAIL of SCLM product support?


if instead asking stupid questions You' d follow on to my implicit question, You might get better results

that' s not an issue that SCLM support will ever bother taking care of!

it is not an SCLM issue per se,
rather a insufficient/wrong understanding of SCLM customization
aka an USER implementation error
Back to top
View user's profile Send private message
dick scherrer

Moderator Emeritus


Joined: 23 Nov 2006
Posts: 19244
Location: Inside the Matrix

PostPosted: Wed Dec 15, 2010 9:50 am
Reply with quote

Hello,

Various product support groups will help with customization for a new user. . .

They do expect that a minimal bit of guidance will be sufficient as they are not in the business of teachning/training.

You might ask which training they would recommend.
Back to top
View user's profile Send private message
enrico-sorichetti

Superior Member


Joined: 14 Mar 2007
Posts: 10873
Location: italy

PostPosted: Wed Dec 15, 2010 9:54 am
Reply with quote

Hi Dick!

I have a small SCLM project defined, so that I can check the answers I give to people who deserve to be helped,
but in this case ....

I just looked at the TS profile and, guess what ...
Quote:
Occupation: IBMer
Mainframe Skills: SYSTEM ADM

just another IBMer,
does not even know how to get info inside his own organization

IBM makes the money and we do the work! icon_evil.gif
Back to top
View user's profile Send private message
dick scherrer

Moderator Emeritus


Joined: 23 Nov 2006
Posts: 19244
Location: Inside the Matrix

PostPosted: Wed Dec 15, 2010 8:19 pm
Reply with quote

Hi Enrico,

Quote:
just another IBMer,
does not even know how to get info inside his own organization
If the organiztion (IBM or other) does not provide some kind of infrastructure training for the new and unexperienced people they hire, how is the new person to know/learn?

Sometimes i believe organizations are trying to get by spending as little as possible, but often there aren't properly trained (let alone experienced) people available. I'm sometimes invited to participate in technical interviews in the last few years and it is really scary the lack of depth available.

Back when i had a "real" job and was a hiring manager, the problem was making a choice between multiple highly qualified people.

d
Back to top
View user's profile Send private message
as4578

New User


Joined: 24 Jun 2010
Posts: 12
Location: China

PostPosted: Thu Dec 16, 2010 7:05 am
Reply with quote

The reedbook supplied by IBM is useful as a reference(like a dictionary), but not friendly for a new user.

If you know the knowledge, you can find some help from the redbooks.
If you are a jackaroo, it gets more confusing after reading the redbooks.
Back to top
View user's profile Send private message
Robert Sample

Global Moderator


Joined: 06 Jun 2008
Posts: 8696
Location: Dubuque, Iowa, USA

PostPosted: Thu Dec 16, 2010 7:28 am
Reply with quote

Redbook SG24-7392, Getting Started with SCLM: A Practical Guide to SCLM and SCLM Advanced Edition seems pretty good at step-by-step setup of test projects -- I don't use SCLM, but I could certainly follow the directions provided.
Back to top
View user's profile Send private message
as4578

New User


Joined: 24 Jun 2010
Posts: 12
Location: China

PostPosted: Thu Dec 16, 2010 7:31 am
Reply with quote

sure, I am reading this book now.
Back to top
View user's profile Send private message
as4578

New User


Joined: 24 Jun 2010
Posts: 12
Location: China

PostPosted: Tue Dec 21, 2010 10:17 am
Reply with quote

I got the solution from a senior SYSTEM ADM.

On the logonon screen,specify a larger Size and it works.

Size ===> xxxx


Thanks for your support,Enrico and Dick.
Back to top
View user's profile Send private message
dick scherrer

Moderator Emeritus


Joined: 23 Nov 2006
Posts: 19244
Location: Inside the Matrix

PostPosted: Tue Dec 21, 2010 10:26 am
Reply with quote

Good to hear it is resolved - thank you for letting us know icon_smile.gif

d
Back to top
View user's profile Send private message
View previous topic :: :: View next topic  
Post new topic   Reply to topic View Bookmarks
All times are GMT + 6 Hours
Forum Index -> IBM Tools

 


Similar Topics
Topic Forum Replies
No new posts Error to read log with rexx CLIST & REXX 11
No new posts Error when install DB2 DB2 2
No new posts CLIST - Virtual storage allocation error CLIST & REXX 5
No new posts Build a record in output file and rep... DFSORT/ICETOOL 11
No new posts EZT program to build a flat file with... All Other Mainframe Topics 9
Search our Forums: