GCruz
New User
Joined: 11 Feb 2010 Posts: 4 Location: Florida
|
|
|
|
PLS SOMEONE HELP. I AM GETTING AN ERROR WRITING FROM A VB TO VB FILE THE FIRST 17 POSITIONS ARE REGULAR EBCIDIC FOR THIS SYSIN ( I ALSO WANT TO GOT FROM PD TO ZD) SYSIN IS AS FOLLOWS: SYSIN :
OPTION COPY
OUTFIL BUILD=(22:22,7,PD,TO=ZD,LENGTH=13,
29:29,6,PD,TO=ZD,LENGTH=11,
35:35,6,PD,TO=ZD,LENGTH=11,
41:41,6,PD,TO=ZD,LENGTH=11,
47:47,6,PD,TO=ZD,LENGTH=11)
WER276B SYSDIAG= 1903157, 5555012, 5555012, 8397225
WER164B 6,896K BYTES OF VIRTUAL STORAGE AVAILABLE, MAX REQUESTED
WER164B 40K BYTES RESERVE REQUESTED, 1,004K BYTES USED
WER146B 20K BYTES OF EMERGENCY SPACE ALLOCATED
WER108I SORTIN : RECFM=VB ; LRECL= 52; BLKSIZE= 27998
WER235A SORTOUT OUTREC RDW NOT INCLUDED |
|
superk
Global Moderator
Joined: 26 Apr 2004 Posts: 4652 Location: Raleigh, NC, USA
|
|
|
|
From another post:
Quote: |
WER235A OUTREC RDW NOT INCLUDED |
SyncSort 16.34 for z/OS 1.2 Programmer’s Guide wrote: |
WER235A [ddname] {INREC,OUTREC,REFORMAT} RDW NOT INCLUDED
EXPLANATION: The ddname will be SORTOUT, SORTOFxx, SORTOFx or the ddname provided by an OUTFIL FNAMES parameter. Four bytes must be provided for the RDW of the variable-length output record in the FIELDS parameter of the INREC, OUTREC, OUTFIL OUTREC, or REFORMAT specification. These bytes must appear at the beginning of the record and must not be edited. For REFORMAT, the RDW must be specified as coming from a variable-length join input data set. |
|
|