Hi All,
I am getiing abend U0271 while restarting IMS batch job.
Can somebody help me how to eliminate this error?
Thanks,
Dipak. |
|
| Back to top |
|
 |
Bitneuker
CICS Moderator

Joined: 07 Nov 2005 Posts: 1104 Location: The Netherlands at Hole 19
|
|
|
|
| GSAM involved? |
|
| Back to top |
|
 |
dipak2805
New User
Joined: 20 Aug 2007 Posts: 4 Location: Pune
|
|
|
|
Hi,
I am using the GSAM as output file. Cab you please suggest how to eliminate this error?
Thanks,
Dipak. |
|
| Back to top |
|
 |
Bitneuker
CICS Moderator

Joined: 07 Nov 2005 Posts: 1104 Location: The Netherlands at Hole 19
|
|
|
|
| This may have to do with a DISP parameter and probably the GSAM is inaccessable. Try to define it again and make sure you initiate it (open/close). |
|
| Back to top |
|
 |
ederrod
New User
Joined: 06 Jun 2005 Posts: 5 Location: Sao Paulo - Brazil
|
|
|
|
Hello folks,
I've got this same error U0271.
In my case, a BMP program was executing and had a deadlock (U0777). However, I restarted the program with the wrong GSAM file, then I got the U0271, message "DFSZDC00 I/O ERROR DBDNAME=B5824FD0 DDNAME=DB5824FD" (DB5824FD is the GSAM ddname).
The GSAM was a GDG file and I got the abend because the last generation (+0) was not the same one by the time I restarted the program. Then, I indicated the correct GSAM file and the program was restarted successfully.
Regards,
Eder |
|
| Back to top |
|
 |
dick scherrer
Moderator Emeritus

Joined: 23 Nov 2006 Posts: 19243 Location: Inside the Matrix
|
|
|
|
Thank you for sharing your experience
d |
|
| Back to top |
|
 |
Kjeld
Active User

Joined: 15 Dec 2009 Posts: 365 Location: Denmark
|
|
|
|
We have a general standard for BMP jobs not to have DISP=(NEW,... on GSAM output, but preallocate in an earlier jobstep and have DISP=OLD on GSAM output DDs.
If output to GDG is needed, the GSAM DD writes to a temporary file and the new GDG generation is created in a subsequent copy jobstep.
This for simplifying restart modifications if a job has to be restarted in a BMP checkpoint. |
|