IBM Mainframe Forum Index
 
Log In
 
IBM Mainframe Forum Index Mainframe: Search IBM Mainframe Forum: FAQ Register
 

ABEND=S000 U0016 in file copy using SYNCGENR


IBM Mainframe Forums -> JCL & VSAM
Post new topic   Reply to topic
View previous topic :: View next topic  
Author Message
raam_kumar

New User


Joined: 25 Apr 2007
Posts: 44
Location: chennai, India

PostPosted: Fri May 04, 2007 12:36 pm
Reply with quote

Hi
I was trying to use ICEGENER utility to copy a file. But when i submitted the job has abended. the abend code is

ABEND=S000 U0016 REASON=00000000

it is also showing the following code in the spool

WER239A TYPE PARAMETER REQUIRED

my objective is just to copy a PS file into another file using ICEGENER

here is the jcl which i have used
Code:

//ICEGENER EXEC PGM=ICEGENER
//SYSUT1   DD DISP=SHR,DSN=<dsnname>
//SYSUT2  DD  DSN=<dsn name>,             
//             DISP=(,CATLG,DELETE),                                         
//             SPACE=(CYL,(500,50),RLSE),MGMTCLAS=WORKM
//SYSPRINT DD  SYSOUT=*                               
//SYSUDUMP DD SYSOUT=*                                 
//SYSIN    DD DUMMY                 


am i missing some thing here?
Back to top
View user's profile Send private message
expat

Global Moderator


Joined: 14 Mar 2007
Posts: 8798
Location: Welsh Wales

PostPosted: Fri May 04, 2007 12:44 pm
Reply with quote

From the message shown, you have SYNCSORT rather than DFSORT.

Change the PGM= to IEBGENER and try that, although some shops will default IEBGENER to ICEGENER (or the SYNCSORT equivilent).
Back to top
View user's profile Send private message
superk

Global Moderator


Joined: 26 Apr 2004
Posts: 4652
Location: Raleigh, NC, USA

PostPosted: Fri May 04, 2007 12:44 pm
Reply with quote

What is the description of the message "WER239A TYPE PARAMETER REQUIRED"?
Back to top
View user's profile Send private message
dick scherrer

Moderator Emeritus


Joined: 23 Nov 2006
Posts: 19243
Location: Inside the Matrix

PostPosted: Fri May 04, 2007 1:16 pm
Reply with quote

Hello,

The WER message you posted may be found in the Syncsort documentation. If your organization is a licensed user, the documentatin is available for free.

Does this step use VSAM?
Back to top
View user's profile Send private message
raam_kumar

New User


Joined: 25 Apr 2007
Posts: 44
Location: chennai, India

PostPosted: Fri May 04, 2007 1:28 pm
Reply with quote

Hi
Mystep is not using VSAM. My input is a PS file only
Back to top
View user's profile Send private message
expat

Global Moderator


Joined: 14 Mar 2007
Posts: 8798
Location: Welsh Wales

PostPosted: Fri May 04, 2007 1:35 pm
Reply with quote

And have you tried IEBGENER yet ?
Back to top
View user's profile Send private message
raam_kumar

New User


Joined: 25 Apr 2007
Posts: 44
Location: chennai, India

PostPosted: Fri May 04, 2007 2:55 pm
Reply with quote

Hi expat

i have tried this using IEBGENER. it is working fine. my objective is to try using ICEGENER and analyze the cpu time.
Back to top
View user's profile Send private message
expat

Global Moderator


Joined: 14 Mar 2007
Posts: 8798
Location: Welsh Wales

PostPosted: Fri May 04, 2007 3:09 pm
Reply with quote

As far as I know, ICEGENER is a component of DFSORT rather than SYNCSORT which you have installed at your shop.
Back to top
View user's profile Send private message
dick scherrer

Moderator Emeritus


Joined: 23 Nov 2006
Posts: 19243
Location: Inside the Matrix

PostPosted: Fri May 04, 2007 7:39 pm
Reply with quote

Hello,

Yes, if you are able to execute ICEGENER, it is most likely that the program name is an alias of Syncsort or possibly SYNCTOOL. No matter which, you most likely do not have the ICExxx modules as they are not delivered with Syncsort.

Many Syncsort sites do intercept simple IEBGENER copy jobs and substitute Syncsort dynamically as it will copy more efficiently than IEBGENER (the same is true of DFSORT as well).

If you get WERxxxx messages from a step, that step is most likely executing code from Syncsort.

The reason i asked about VSAM is that the "WER239A TYPE PARAMETER REQUIRED " message can relate to vsam. When i sent the earlier reply, i didn't have this available:
Quote:
WER239A TYPE PARAMETER REQUIRED
EXPLANATION: There was a VSAM input or output file but the TYPE
parameter was not specified. Or, an E15 or E32 exit routine is passing
all of the records to the sort/merge (no SORTIN/SORTINnn), but the
TYPE parameter was not specified on the RECORD control statement.


Good luck and we're here if there are questions icon_smile.gif
Back to top
View user's profile Send private message
Frank Yaeger

DFSORT Developer


Joined: 15 Feb 2005
Posts: 7129
Location: San Jose, CA

PostPosted: Fri May 04, 2007 9:06 pm
Reply with quote

raam,

You are using Syncsort's SYNCGENR, not DFSORT's ICEGENER. I believe Syncsort ships ICEGENER as an alias for SYNCGENR.
Back to top
View user's profile Send private message
View previous topic : : View next topic  
Post new topic   Reply to topic All times are GMT + 6 Hours
Forum Index -> JCL & VSAM

 


Similar Topics
Topic Forum Replies
No new posts IGYPG3178-I when compiling a pgm read... COBOL Programming 6
No new posts FileAid move data from two files to o... Compuware & Other Tools 5
No new posts Sorting date into YYYYMMDD, and creat... DFSORT/ICETOOL 13
No new posts To Sort detail records in a file with... SYNCSORT 5
No new posts Avoid job abend on dataset held by us... JCL & VSAM 6
Search our Forums:


Back to Top