Two PDSEs to be compared are: I201844.COPY and I201844.COPY.A01
The members of both are: A, B, C。
RC = 8 and job log saying“IEB205I USER DATA FIELDS UNEQUAL”。
What's the meaning of "SER DATA FIELDS" here?
What does it mean by "USER DATA FIELDS UNEQUAL"
Can the RC be 0? whether yes or not, what's the reason?
JOB
--------------------------------------------------------------------
//COMPR JOB ACCT#,'MASSA',NOTIFY=&SYSUID,
// MSGLEVEL=(1,1),CLASS=A,MSGCLASS=H
//STEP EXEC PGM=IEBCOMPR
//SYSPRINT DD SYSOUT=*
//SYSUT1 DD DSN=I201844.COPY,UNIT=3390,DISP=SHR
//* DCB=(LRECL=80,RECFM=FB,BLKSIZE=3200),
//* VOLUME=SER=DMTD02
//SYSUT2 DD DSN=I201844.COPY.A01,UNIT=3390,DISP=SHR
//* DCB=(LRECL=80,RECFM=FB,BLKSIZE=3200),
//* VOLUME=SER=DMTD01
//SYSIN DD *
COMPARE TYPORG=PO
/*
**************************** Bottom of Data *************
--------------------------------------------------------------------
JOB LOG
--------------------------------------------------------------------
********************************* TOP OF DATA **********************
COMPARE UTILITY
COMPARE TYPORG=PO
IEB205I USER DATA FIELDS UNEQUAL
DDNAME = SYSUT1 MEMBER NAME = A
010100300108093F0108099F1422000100010001C9F2F0F1F8F4F4404040
DDNAME = SYSUT2 MEMBER NAME = A
010100540108093F0108099F1422000100010001C9F2F0F1F8F4F4404040
IEB205I USER DATA FIELDS UNEQUAL
DDNAME = SYSUT1 MEMBER NAME = B
010100370108093F0108099F1422000100010001C9F2F0F1F8F4F4404040
DDNAME = SYSUT2 MEMBER NAME = B
010100010108093F0108099F1423000100010001C9F2F0F1F8F4F4404040
IEB205I USER DATA FIELDS UNEQUAL
DDNAME = SYSUT1 MEMBER NAME = C
010100430108093F0108099F1422000100010001C9F2F0F1F8F4F4404040
DDNAME = SYSUT2 MEMBER NAME = C
-------------------------------------------------------------------- |
|
Back to top |
|
|
expat
Global Moderator
Joined: 14 Mar 2007 Posts: 8797 Location: Welsh Wales
|
|
|
|
Try option 3.12 under ISPF and see what happens |
|
Back to top |
|
|
enrico-sorichetti
Superior Member
Joined: 14 Mar 2007 Posts: 10873 Location: italy
|
|
|
|
Quote: |
IEB205I USER DATA FIELDS UNEQUAL
Explanation: The user data fields or TTRs of the SYSUT1 and SYSUT2 data sets are not identical.
System Action: The fields are listed and processing continues. The return code is 8.
Source: |
the ispf statistics look different |
|
Back to top |
|
|
vivid8474
New User
Joined: 13 Mar 2008 Posts: 6 Location: CN
|
|
|
|
USER DATA FIELDS is stored in data set directory.
How to view USER DATA FIELDS information? |
|
Back to top |
|
|
enrico-sorichetti
Superior Member
Joined: 14 Mar 2007 Posts: 10873 Location: italy
|
|
|
|
edit/view/browse, member list the two pds/pdsE and look at the columns after the member name
those are the ISPF statistics and should be different |
|
Back to top |
|
|
|