View previous topic :: View next topic
|
Author |
Message |
ajayvamsi
New User
Joined: 21 Jul 2005 Posts: 56 Location: Hyderabad
|
|
|
|
hi
could any one help me with the COMPLETE SYNTAX of CICS SEND TEXT since I am facing soc7 problem.
thanks
ajay |
|
Back to top |
|
|
enrico-sorichetti
Superior Member
Joined: 14 Mar 2007 Posts: 10873 Location: italy
|
|
|
|
What about clicking on the Manuala link at the very top of the page ???
( white text on grey background, second choie after Portal ) |
|
Back to top |
|
|
Earl
Active User
Joined: 17 Jun 2007 Posts: 148 Location: oklahoma
|
|
|
|
send text does not normally cause a SOC7' << do you mean ASRA ??
please provide an example of your cics send text statement. |
|
Back to top |
|
|
ajayvamsi
New User
Joined: 21 Jul 2005 Posts: 56 Location: Hyderabad
|
|
|
|
it is not present in manual sir I have checked it |
|
Back to top |
|
|
enrico-sorichetti
Superior Member
Joined: 14 Mar 2007 Posts: 10873 Location: italy
|
|
|
|
Quote: |
t is not present in manual sir I have checked it |
It would be a good idea to go and see an ophthalmologist...
Quote: |
1.203 SEND TEXT
Function
Send data without mapping. The keywords are separated into those supported by standard and full-function BMS. For further information about BMS, see the CICS/ESA Application Programming Guide.
Command syntax
___ SEND TEXT __________________________________________________________
| |
| SEND TEXT |
| Standard BMS |
| FROM(data-area) |
| [LENGTH(data-value)] |
| [CURSOR(data-value)] |
| [FORMFEED] |
| [ERASE] |
| [PRINT] |
| [FREEKB] |
| [ALARM] |
| [NLEOM] |
| [[LDC(name)|[OUTPARTN(name)] |
| [ACTPARTN(name)]] |
| [MSR(data-value)] |
| Full BMS |
| [SET(ptr-ref)|PAGING| |
| TERMINAL[WAIT][LAST]] |
| [REQID(name)] |
| [HEADER(data-area)] |
| [TRAILER(data-area)] |
| [JUSTIFY(data-value)|JUSFIRST| |
| JUSLAST] |
| [ACCUM] |
| [L40|L64|L80|HONEOM] |
| Conditions: IGREQCD, IGREQID, INVLDC, INVPARTN, |
| INVREQ, LENGERR, RETPAGE, TSIOERR, WRBRK |
| |
| |
|________________________________________________________________________|
SEND TEXT sends text data without mapping. The text is split into lines
of the same width as the terminal, such that words are not broken across
line boundaries. If the text exceeds a page, it is split into pages that
fit on the terminal with application-defined headers and trailers.
Subtopics:
* 1.203.1 SEND TEXT options
* 1.203.2 SEND TEXT conditions
|
the quoted text was right there
I bet You didn' even read my signature ..... |
|
Back to top |
|
|
Earl
Active User
Joined: 17 Jun 2007 Posts: 148 Location: oklahoma
|
|
|
|
ajayvamsi
It would help if you would supply a sample of the 'send text' command
from your source code that you say is causing the problem. |
|
Back to top |
|
|
|