View previous topic :: View next topic
|
Author |
Message |
antonio_mariche
New User
Joined: 08 Mar 2007 Posts: 2 Location: Mexico
|
|
|
|
I'm trying to make an alternate index but I received this response:
IGD17103I CATALOG ERROR WHILE DEFINING VSAM DATA SET
X050.USER.HISTORY.AIX
RETURN CODE IS 80 REASON CODE IS 0 IGG0CLET
IGD306I UNEXPECTED ERROR DURING IGG0CLET PROCESSING
RETURN CODE 80 REASON CODE 0
THE MODULE THAT DETECTED THE ERROR IS IGDVTSCU
SMS MODULE TRACE BACK - VTSCU VTSCT VTSCH VTSCG VTSCD VTSCC VTSCR SSIRT
SYMPTOM RECORD CREATED, PROBLEM ID IS IGD19459
IGD17219I UNABLE TO CONTINUE DEFINE OF DATA SET
X050.USER.HISTORY.AIX
IDC3022I INVALID RELATED OBJECT
IDC3009I ** VSAM CATALOG RETURN CODE IS 80 - REASON CODE IS IGG0CLET-0
IDC3003I FUNCTION TERMINATED. CONDITION CODE IS 12
I has already make the file that I thing is relative object.
I don't know the REASON CODE IGG0CLET-0 means. ?Can you explain this code please? |
|
Back to top |
|
|
dick scherrer
Moderator Emeritus
Joined: 23 Nov 2006 Posts: 19244 Location: Inside the Matrix
|
|
|
|
Hello,
Please post your IDCAMS control statements for both the cluster and the alternate index. |
|
Back to top |
|
|
enrico-sorichetti
Superior Member
Joined: 14 Mar 2007 Posts: 10873 Location: italy
|
|
|
|
usually the AMS messages bounce You to an IDC prefix message..
You should have noticed if You had CARED to look at the messages and codes
anyway I pasted the relevant info from the manual
Quote: |
IDC3009I VSAM CATALOG RETURN CODE IS return-code - REASON CODE IS IGGOCLaa
- reason-code
|
Quote: |
RETURN CODE 80
Explanation: Incorrect related object. The object specified in the
RELATE parameter of a DEFINE command does not exist, or is improper
for the type of object being defined.
Reason Code Description
0 Explanation: The related object is reusable.
Programmer Response: Correct the DEFINE command so that the entry named in the RELATE parameter is proper for the type of object being defined.
|
regards |
|
Back to top |
|
|
expat
Global Moderator
Joined: 14 Mar 2007 Posts: 8797 Location: Welsh Wales
|
|
|
|
You have defined and loaded/initialised the base cluster, haven't you ? |
|
Back to top |
|
|
antonio_mariche
New User
Joined: 08 Mar 2007 Posts: 2 Location: Mexico
|
|
|
|
I tank you all of you, I redefine my vsam as no reusable, and work. |
|
Back to top |
|
|
dick scherrer
Moderator Emeritus
Joined: 23 Nov 2006 Posts: 19244 Location: Inside the Matrix
|
|
|
|
You're welcome.
Thank you for posting your solution. |
|
Back to top |
|
|
|