I got a SOC7 abend and this is the dump ...
so can u please explain me about this ... is BLW a value in Input file ??
how to read this BLW and wht is the value of 0000+47A ??
Please help me out...
Most recently referenced data items:
Data Item . . . . . . . . : BLW=0000+47A
At Address. . . . . . . : 000A0B3A
Length. . . . . . . . . : X'B'
Data Item Storage . . . : 40404040 40404040 404040 * *
Data Item . . . . . . . . : BLW=0000+486
At Address. . . . . . . : 000A0B46
Length. . . . . . . . . : X'2'
Data Item Storage . . . : 4040 * * |
|
Back to top |
|
|
meetreks
New User
Joined: 28 Sep 2006 Posts: 26 Location: Edinburgh
|
|
|
|
These are the steps to find the same.
1. First go the compile listing of the program in question.
2. The find BLW=000
3. This will give you the start of the BLW cell 000. Then the field which caused the problem is at 486 bytes from the start of this cell. So what you have found till now is the name of the working storage field which has caused the S0C7.
4. The next step is to find the place within the program where is has abended.
5. This is given by the address A0B46. Find for this address in the program and you will find this variable nearer the address.
--> I have assumed that the BLW 000, 486 is the field causing the problem at address A0B46.
Hope this helps. |
|
Back to top |
|
|
prashanth1
New User
Joined: 27 Sep 2006 Posts: 47 Location: Hyderabad
|
|
|
|
Sri Ranjan,
Let me know, whether r u using Abend-Aid r not.
If yes , I will let u know how to read the BLW cells with their displacements.
Regards,
Prashanth1 |
|