| Author |
Message |
lrawat
New User
Joined: 02 Feb 2008 Posts: 15 Location: usa
|
|
|
|
friends, is the channel and container available with CICS 6.3.0?
EXEC CICS PUT CONTAINER (CUSTOMER-NO) CHANNEL (INQUIRY-CHANNEL)
FROM (CUSTNO) FLENGTH (LENGTH OF CUSTNO)
END-EXEC.
EXEC CICS LINK PROGRAM ('WMC120U') CHANNEL (INQUIRY-CHANNEL).
END-EXEC.
I am trying to compile above code in CICS 6.3.0 and getting below compilation error.
OPTION 'CHANNEL' IS NOT VALID AND IS IGNORED.
'END-EXEC' ASSUMED AFTER 'PROGRAM ('WMC120U')'. |
|
| Back to top |
|
 |
References
|
Posted: Tue Apr 29, 2008 2:36 am Post subject: Re: Channel & container with CICS 6.3.0 |
 |
|
|
 |
UmeySan
Senior Member
Joined: 22 Aug 2006 Posts: 498 Location: Germany
|
|
|
|
Hi !
If i remember correctly, CICS TransaktionServer V3.1, or later, must be present.
Regards, UmeySan |
|
| Back to top |
|
 |
CICS Guy
Senior Member
Joined: 18 Jul 2007 Posts: 999 Location: At my desk
|
|
|
|
Yes, looks like a minof 3.1..
Just wonder why the prior PUT didn't fail...... |
|
| Back to top |
|
 |
SCARCEBOYZ
New User
Joined: 16 May 2005 Posts: 20 Location: Millenium Business Park, Mumbai
|
|
| Back to top |
|
 |
|
|