| Author |
Message |
lrawat
New User
Joined: 02 Feb 2008 Posts: 19 Location: usa
|
|
|
|
"IEW2456E 9207 SYMBOL IDMS UNRESOLVED. MEMBER COULD NOT BE INCLUDED FROM THE DESIGNATED CALL LIBRARY."
Hi friends, I am getting above error message while linking a CICS online program (called by a MQ prog).
Can anyone please guide on the resolution of this prob.
Thanks a lot!!! |
|
| Back to top |
|
 |
References
|
Posted: Mon Mar 03, 2008 10:11 pm Post subject: Re: CICS Linking Error: SYMBOL IDMS UNRESOLVED |
 |
|
|
 |
dbzTHEdinosauer
Senior Member
Joined: 20 Oct 2006 Posts: 1388 Location: germany
|
|
|
|
| include the library containing IDMS in your link jcl. |
|
| Back to top |
|
 |
lrawat
New User
Joined: 02 Feb 2008 Posts: 19 Location: usa
|
|
|
|
| dbzTHEdinosauer wrote: |
| include the library containing IDMS in your link jcl. |
Thanks for the quick reply, Dick.
Can you please advice how can i get that IDMS library you are talking about?
Rite now my link step contains below...
//LINK.SYSLIB DD DSN=&CICSLNK,DISP=SHR,DCB=BLKSIZE=13030
// DD DSN=&SYSCOB,DISP=SHR
// DD DSN=&SUBLIB,DISP=SHR
// DD DSN=S4PROD.XPD2.SUBR.OBJLIB,DISP=SHR
// DD DSN=SYS5.IDMS.CV44T.LOADLIB(IDMSCINT),DISP=SHR
//LINK.SYSLIN DD DSN=&CICSCOB(DFHEILIC),DISP=SHR
// DD DSN=&COBOUT,DISP=(OLD,DELETE) |
|
| Back to top |
|
 |
Bill O'Boyle
Active User
Joined: 14 Jan 2008 Posts: 270 Location: Orlando, FL, USA
|
|
|
|
Most likely, you'll have to check with your IDMS Technical person in your shop, because the DSN's are usually site-specific.
Bill |
|
| Back to top |
|
 |
lrawat
New User
Joined: 02 Feb 2008 Posts: 19 Location: usa
|
|
|
|
| Bill O'Boyle wrote: |
Most likely, you'll have to check with your IDMS Technical person in your shop, because the DSN's are usually site-specific.
Bill |
thanks Bill.
I would seek help from my technical person. I would ask for "library containing IDMS" as suggested by Dick.
Thanks a lot Dick & Bill!!! |
|
| Back to top |
|
 |
lrawat
New User
Joined: 02 Feb 2008 Posts: 19 Location: usa
|
|
|
|
| dbzTHEdinosauer wrote: |
| include the library containing IDMS in your link jcl. |
Hi Friends,
i got my prog compiled and linked, actually it was code bug.
protocol mode was wrongly mentioned as "batch" instead of "cics-exec".
thanks for all your help ...
WAS : >>
PROTOCOL.
MODE IS BATCH DEBUG.
IDMS-RECORDS MANUAL.
CHANGED TO : >>
PROTOCOL.
MODE IS CICS-EXEC DEBUG.
IDMS-RECORDS MANUAL. |
|
| Back to top |
|
 |
dbzTHEdinosauer
Senior Member
Joined: 20 Oct 2006 Posts: 1388 Location: germany
|
|
|
|
thx for getting back and providing the info.
helpful for future questions. |
|
| Back to top |
|
 |
|
|