Has IBM introduced any new instruction called "LT"

 
Post new topic   Reply to topic    IBMMAINFRAMES.com Support Forums -> PL/I & ASSEMBLER
Author Message
saravananj

New User


Joined: 23 Nov 2007
Posts: 16
Location: Chennai

PostPosted: Mon May 05, 2008 1:51 pm    Post subject: Has IBM introduced any new instruction called "LT"
Reply with quote

Has IBM introduced any new instruction called "LT"??

Previously we were having a user written macro "LT" which is nothing but ICM with a mask of 15.

Very recently our shop migrated to z/OS 1.7 and suddenly when we tried to compile our old assembler programs, in the listing we found the following details for LT instruction,
Quote:
0001D2 E342 0000 0012 00000 599 LT R4,0(R2) GET

Clearly "E3" is not the opcode for ICM instruction. I did a search on POPS but was unsuccessful in finding any details about LT instruction.
Back to top
View user's profile Send private message
References
PostPosted: Mon May 05, 2008 1:51 pm    Post subject: Re: Has IBM introduced any new instruction called "LT" Reply with quote

enrico-sorichetti

Global Moderator


Joined: 14 Mar 2007
Posts: 2565
Location: italy

PostPosted: Mon May 05, 2008 3:33 pm    Post subject: Reply to: Has IBM introduced any new instruction called &quo
Reply with quote

Maybe You were looking at the wrong level of the docs...

SA22-7832-06 has it as LOAD AND TEST
Back to top
View user's profile Send private message
saravananj

New User


Joined: 23 Nov 2007
Posts: 16
Location: Chennai

PostPosted: Mon May 05, 2008 4:05 pm    Post subject: Re: Reply to: Has IBM introduced any new instruction called
Reply with quote

enrico-sorichetti wrote:
Maybe You were looking at the wrong level of the docs...

SA22-7832-06 has it as LOAD AND TEST


Very true the version of POPS that I had seems to be a bit old. Thanks for the pointer.
Back to top