| IBM MAINFRAME HELP & SUPPORT FORUMS Technical Forums for IBM Mainframe Applications like COBOL, JCL, CICS, DB2, FileAid, DFSORT, Endevor, Xpediter, CoolGen, CA-7&11, AbendAid, IMS, IDMS, PL/I, MqSeries, SyncSort, Assembler, ChangeMan, Easytrieve, InterTest, REXX, CLIST etc...
|
| View previous topic :: View next topic |
| Author |
Message |
dhamuv
Joined: 10 Feb 2008
Posts: 1
Location: Chennai
|
| Posted: Wed Aug 20, 2008 12:37 pm Post subject: Will s9(5)v99 packed-decimal fits with s9(7) packed-decimal |
|
|
If my input data is in s9(5)v99 packed-decimal
but in program i declared it as s9(7) packed-decimal
will it accept ? |
|
| Back to top |
|
Srihari Gonugunta
Joined: 14 Sep 2007
Posts: 184
Location: Pune
|
| Posted: Wed Aug 20, 2008 2:49 pm Post subject: |
|
|
| You will lose the decimal part. |
|
| Back to top |
|
dbzTHEdinosauer
Joined: 20 Oct 2006
Posts: 1639
Location: germany
|
| Posted: Wed Aug 20, 2008 4:19 pm Post subject: |
|
|
| divide s9(7)-field by 100 giving s9(5)v99-field. |
|
| Back to top |
|
Bill O'Boyle
Joined: 14 Jan 2008
Posts: 345
Location: Orlando, FL, USA
|
| Posted: Fri Aug 22, 2008 4:03 pm Post subject: Re: Will s9(5)v99 packed-decimal fits with s9(7) packed-deci |
|
|
Redefine the PIC S9(07) PACKED-DECIMAL field as PIC S9(05)V99 PACKED-DECIMAL and perform a straight move.
Then, all will be forgiven.... :wink:
Bill |
|
| Back to top |
|
| |
THIS IS AN ARCIVE FORUM IN READ ONLY MODE. IF YOU WANT TO ASK YOUR DOUBTS USE THE ACTUAL FORUM
|