Hi,
There is a job which abends with S0C4 and REASON=00000010 and runs fine when we restart the job from the abended step.
Here is a copy of the message.
DT STEP020 AR2190DT - COMPLETION CODE - SYSTEM=0C4 USER=0000 REASON=00000010
INHOUSE.LINKLIB RETAINED, DDNAME=STEPLIB
.IDMS.CVPROD.AIDMS.LOADLIB KEPT
Any help in identifying the issue will be appreciated.
Thanks & Regards,
Srinath D |
|
Back to top |
|
|
Anuj Dhawan
Superior Member
Joined: 22 Apr 2006 Posts: 6250 Location: Mumbai, India
|
|
|
|
This is very less information to have some constructive answer. Only thing which one can suggest - did you look for "S0C4 and REASON=00000010" & follow what it suggests. |
|
Back to top |
|
|
dick scherrer
Moderator Emeritus
Joined: 23 Nov 2006 Posts: 19244 Location: Inside the Matrix
|
|
|
|
Hello,
You need to post more complete info about your abend.
What were you running (some application program or some utility)?
Posting the run jcl should help us help you.
Does this fail every time on the "first run" and then works on the restart?
When posting info, you need to be complete - include any message ids. |
|
Back to top |
|
|
Nic Clouston
Global Moderator
Joined: 10 May 2007 Posts: 2455 Location: Hampshire, UK
|
|
|
|
Also, what sort of restart - from the beginning or a checkpoint of some sort? |
|