View previous topic :: View next topic
|
Author |
Message |
amar143
New User
Joined: 11 Nov 2010 Posts: 4 Location: India
|
|
|
|
If limit of GDG(255) reached and I want to create another 100 generations, How can i create that? And what will happen with older 255 generations. |
|
Back to top |
|
|
Robert Sample
Global Moderator
Joined: 06 Jun 2008 Posts: 8696 Location: Dubuque, Iowa, USA
|
|
|
|
1. The theoretical limit of cataloged generations is 255 generations -- the actual limit will depend upon how the GDG was defined.
2. The actual generation number can go up to 9000 (i.e., G8999V00 is a valid generation number).
3. Assuing you created a GDG with LIMIT(255) and you add 100 generations, then the normal processing will occur -- the oldest 100 generations will be removed from the catalog (disposition depending upon a variety of factors, such as whether or not the GDG is SMS-managed, whether the GDG was defined with ERASE and so forth) and the new 100 generations will be in the catalog. The catalog would start with G0001V00 through G0255V00 and wind up with G0101V00 through G0355V00.
Since you seem completely and totally clueless about generation data groups, why don't you tell us the actual problem you THINK you have and let us help you clarify it? |
|
Back to top |
|
|
Peter cobolskolan
Active User
Joined: 06 Feb 2012 Posts: 104 Location: Sweden
|
|
|
|
You can use IDCAMS and ALTER to give the GDG a new LIMIT(), if the limit is incorrect, otherwise as Robert suggested. |
|
Back to top |
|
|
amar143
New User
Joined: 11 Nov 2010 Posts: 4 Location: India
|
|
|
|
Thanks very much Robert for your clarification, There is no practical scenario I am facing with but According to theoretical description, I come to know that limit of GDG creation is 255 so I had that doubt. Now what will happen, if generations goes beyond 9000 (i.e., G8999V00 is a valid generation number). |
|
Back to top |
|
|
Robert Sample
Global Moderator
Joined: 06 Jun 2008 Posts: 8696 Location: Dubuque, Iowa, USA
|
|
|
|
amar143, this is NOT a manual reading service. Please find the JCL User's Guide (hint: there's a button at the top of THIS page that will let you review it) and read Appendix B on Generation Data Sets to find the answer to your question. |
|
Back to top |
|
|
Phrzby Phil
Senior Member
Joined: 31 Oct 2006 Posts: 1042 Location: Richmond, Virginia
|
|
|
|
Or - Experiment!!
That's not just a chemistry exercise.
You might just become your site's expert. (Then you'll be cited.) |
|
Back to top |
|
|
Anuj Dhawan
Superior Member
Joined: 22 Apr 2006 Posts: 6250 Location: Mumbai, India
|
|
|
|
Quote: |
Now what will happen, if generations goes beyond 9000 |
Don't hold your breath, you still have 999 to go! |
|
Back to top |
|
|
Pete Wilson
Active Member
Joined: 31 Dec 2009 Posts: 581 Location: London
|
|
|
|
should we mention versions!
You'll find they go up to G9999V00 and then back to G0001V00 again. If you have both of those generation existing and you reference the (0) relative generation it would be to G0001V00 and G9999V00 would be (-1). |
|
Back to top |
|
|
|