Hi All,

I am getting following issue when trying to create DDIO file in Xpeditor.

Below are steps followed by me

1.option 5(UTILITIES) from Xpeditor Main menu

2. then 3 for DDIO file

3.Then trying to create DDIO file

Code:
 Commands:  SEtup      DDIOCALC (DDIO calculator)                               
            DD (DDIO tutorial)   SD (SD/DB tutorial)   LP (LP tutorial)         
                                                                               
 Processing Options for S/Member List:        Source Browsing Options:         
     Confirm Delete ===> YES (Yes or No)               Unit ===> VIO           
   Show print setup ===> YES (Yes or No)           Blocking ===> 10             
           Language ===> ENGLISH           (ENGLISH/JAPANESE/USAMIX/USAUC)     
                                                                               
 SEL Options:  C (Create)  I (Info)  S (Member List)  A (Adv Function)         
               M (Move/Copy/Export/Import)                                     
                                                                               
     SEL     ---- Source Listing Shared Directories/Databases/DDIO files ----   
      c      'CGNLST.PHA.DDIO'____________________________                     
      _  (1)  'CGNLST.PK1.DDIO'                                                 
      _  (2)  'CGNLST.PK.XPED3.DDIO'                                           
      _  (3)  'CGNLST.PK.XPED2.DDIO'                                           
      _  (4)  'CGNLST.VAZID.DDIO'                                               
      _  (5)  'CGNLST.SAMP.DDIO'                                               
      _  (6)  'CGNLST.XPED.DDIO'                                               
      _  (7)  'CGNLST.PK.DDIO'                                                 
         (8)                                                                   


4.then option 1
[/code] Commands: SEtup DD (DDIO tutorial) SD (SD/DB tutorial) LP (LP tutorial)

File Name entered: 'CGNLST.PHA.DDIO'


1 Shared Directory - Create a shared directory
NOTE: At least one database file must be
attached to this shared directory for it
to be functional.

2 Database File - Create a Database that will be attached
to an EXISTING shared directory.

3 DDIO File - Create a non-database DDIO file.

Code:


5.then as in below screen

Commands: SEtup A (Advanced Parms)
DD (DDIO tutorial) SD (SD/DB tutorial) LP (LP tutorial)

Dataset Name ===> 'CGNLST.PHA.DDIO'

Preparation ===> EDITJCL (Batch/Editjcl/Foreground)
Reallocate ===> NO (Yes/No)

Model DSN ===>
Storage Class ===> (optional)
Management Class ===> (optional)
Data Class ===> (optional)
Volume ===> (optional)

Space Units ===> CYLINDERS (Blocks/Tracks/Cylinders)
Primary Quantity ===> 20
OR
Number of Entries ===> (optional)
(This field overrides above space parms & calculates space needed)

Press ENTER to process or enter END command to terminate
Code:


6.then trying to submit the JCL

Commands: SEtup A (Advanced Parms)
DD (DDIO tutorial) SD (SD/DB tutorial) LP (LP tutorial)

Dataset Name ===> 'CGNLST.PHA.DDIO'

Preparation ===> EDITJCL (Batch/Editjcl/Foreground)
Reallocate ===> NO (Yes/No)

Model DSN ===>
Storage Class ===> (optional)
Management Class ===> (optional)
Data Class ===> (optional)
Volume ===> (optional)

Space Units ===> CYLINDERS (Blocks/Tracks/Cylinders)
Primary Quantity ===> 20
OR
Number of Entries ===> (optional)
(This field overrides above space parms & calculates space needed)

Press ENTER to process or enter END command to terminate
Code:


7.but getting below error
********************************* Top of Data ****
STMT NO. MESSAGE
1 IEFC607I JOB HAS NO STEPS
******************************** Bottom of Data **
Code:


Can some one help here
[/quote]
Back to top
View user's profile Send private message
Robert Sample

Global Moderator


Joined: 06 Jun 2008
Posts: 8696
Location: Dubuque, Iowa, USA

PostPosted: Wed Aug 10, 2011 7:45 pm
Reply with quote

My best guess is that whoever did the Compuware Shared Services or Xpediter installation at your site missed one or more of the steps. Contact your site support group for assistance; they can rerun the installation procedure and hopefully find what was missed.

The Compuware Shared Services Installation and Customization Guide manual also contains a batch job that can be used to create a DDIO.
Back to top
View user's profile Send private message
Anuj Dhawan

Superior Member


Joined: 22 Apr 2006
Posts: 6250
Location: Mumbai, India

PostPosted: Wed Aug 10, 2011 8:36 pm
Reply with quote

This might and just might help - start by copy an existing DDIO file to another file, delete all the members of it and use it as your DDIO.
Back to top
View user's profile Send private message
Ed Goodman

Active Member


Joined: 08 Jun 2011
Posts: 556
Location: USA

PostPosted: Wed Aug 10, 2011 8:41 pm
Reply with quote

Did you get a job out at all? What does it look like?
Back to top
View user's profile Send private message
dbzTHEdinosauer

Global Moderator


Joined: 20 Oct 2006
Posts: 6966
Location: porcelain throne

PostPosted: Wed Aug 10, 2011 8:46 pm
Reply with quote

in ISPF options 3.2.V do a listcat of an existing DDIO file.
use the output as a basis
for a define vsam - also part of the 3.2.V option.
Back to top
View user's profile Send private message
phani.mf2011

New User


Joined: 15 Apr 2011
Posts: 17
Location: india

PostPosted: Thu Aug 11, 2011 7:15 pm
Reply with quote

Thanks all,

The problem is resolved,but now I am getting "SCAN timed out" when trying to Convert Compile JCL below is screen shot

Code:
 -------------------- XPEDITER/TSO - CONVERT COMPILE JCL ------- SCAN timed out
 COMMAND ===>                                                                   
                                                                               
 Primary Commands:  blank (Process JCL)   Browse   Edit   SEtup                 
                                                                               
 ISPF Library:                                                                 
   Project ===>                                                                 
   Group   ===>           ===>           ===>           ===>                   
   Type    ===>                                                                 
   Member  ===>                (Blank for member selection list)               
                                                                               
 Other Partitioned or Sequential Dataset:                                       
    Dataset Name ===> 'CGNLST.PK.TEST(XPEDCOB)'                                 
   Volume Serial ===>          (If not cataloged)                               
                                                                               
 Language Processor Related Items:                                             
       DDIO File ===> 'CGNLST.KPC.DDIO'                                         
 Options Dataset ===>                                                           
                                                                               
                                                                               
                                                                               
                                                                               
            Press ENTER to process  or  enter END command to terminate         
                                                                               
                                                                               
Back to top
View user's profile Send private message
Robert Sample

Global Moderator


Joined: 06 Jun 2008
Posts: 8696
Location: Dubuque, Iowa, USA

PostPosted: Thu Aug 11, 2011 7:31 pm
Reply with quote

Did PF1 give you any additional information?
Back to top
View user's profile Send private message
dbzTHEdinosauer

Global Moderator


Joined: 20 Oct 2006
Posts: 6966
Location: porcelain throne

PostPosted: Thu Aug 11, 2011 7:59 pm
Reply with quote

normally scan timed out has more to do with the return of a submit command, which xpeditor does under the covers to verify the jcl.

it could be you site does not want you to 'convert compile jcl'
and has its own process in place.

suggest you talk to your site support.

has nothing to do with the ddio file.
Back to top
View user's profile Send private message
Ed Goodman

Active Member


Joined: 08 Jun 2011
Posts: 556
Location: USA

PostPosted: Thu Aug 11, 2011 9:21 pm
Reply with quote

Look for the place in the panels where you set up the job card. I'd bet it doesn't have your name on it. I got bit by that once...many years ago.

The job would submit with another userid, then the panel would wait until it could read the output, which it couldn't.
Back to top
View user's profile Send private message
View previous topic :: :: View next topic  
Post new topic   Reply to topic View Bookmarks
All times are GMT + 6 Hours
Forum Index -> Compuware & Other Tools

 


Similar Topics
Topic Forum Replies
No new posts SFTP Issue - destination file record ... All Other Mainframe Topics 2
No new posts Issue after ISPF copy to Linklist Lib... TSO/ISPF 1
No new posts Facing ABM3 issue! CICS 3
No new posts Panvalet - 9 Character name - Issue c... CA Products 6
No new posts Issue with EXEC CICS QUERY SECURITY c... CICS 6
Search our Forums:

Back to Top