View previous topic :: View next topic
|
Author |
Message |
ganasrinivasan
New User
Joined: 06 Nov 2006 Posts: 27 Location: Montreal
|
|
|
|
Hi,
In my JCL, I specified RECFM as VB and in COBOL file declaration I specified RECORDING mode as V. I am writing some information to that file. Now the problem is always the o/p file format is coming as VBA instead of VB. due to this one byte is getting truncated.
Thanks,
Gana |
|
Back to top |
|
|
dbzTHEdinosauer
Global Moderator
Joined: 20 Oct 2006 Posts: 6966 Location: porcelain throne
|
|
|
|
stop using write after/before/advancing. |
|
Back to top |
|
|
superk
Global Moderator
Joined: 26 Apr 2004 Posts: 4652 Location: Raleigh, NC, USA
|
|
|
|
OK. So make the LRECL one byte longer. |
|
Back to top |
|
|
ganasrinivasan
New User
Joined: 06 Nov 2006 Posts: 27 Location: Montreal
|
|
|
|
dbzTHEdinosauer : You are awesome!!
It worked!! |
|
Back to top |
|
|
|