Hi All,

When I try to create DDIO using xpediter I am getting the following error. Pls help.

SVM4000I CSWCNSA, RACFSTD.RACFSTD, SYS00287, ATTEMPTING SPACSECA FOR CSWCNSA.CO
BOL.DDIO, SMC004, 1
SVM4855I SET SECONDARY SPACE USING 70% OF PRIMARY ( 2 TRKS) : 1 TRKS
SVM4000I CSWCNSA, RACFSTD.RACFSTD, SYS00287, ATTEMPTING SPACSECR FOR CSWCNSA.CO
BOL.DDIO, SMC004, 123
SVM4001I RECOVERY ATTEMPT FAILED TO PASS FLST/RLST CRITERIA
SVM4000I CSWCNSA, RACFSTD.RACFSTD, SYS00287, ATTEMPTING SPACSECR FOR CSWCNSA.CO
BOL.DDIO, SMC016, 123
SVM4001I RECOVERY ATTEMPT FAILED TO PASS FLST/RLST CRITERIA
SVM4000I CSWCNSA, RACFSTD.RACFSTD, SYS00287, ATTEMPTING SPACSECR FOR CSWCNSA.CO
BOL.DDIO, SMC017, 123
SVM4001I RECOVERY ATTEMPT FAILED TO PASS FLST/RLST CRITERIA
SVM4000I CSWCNSA, RACFSTD.RACFSTD, SYS00287, ATTEMPTING SPACSECR FOR CSWCNSA.CO
BOL.DDIO, SMC012, 123
SVM4001I RECOVERY ATTEMPT FAILED TO PASS FLST/RLST CRITERIA
SVM4000I CSWCNSA, RACFSTD.RACFSTD, SYS00287, ATTEMPTING SPACSECR FOR CSWCNSA.CO
BOL.DDIO, SMC001, 123
SVM4001I RECOVERY ATTEMPT FAILED TO PASS FLST/RLST CRITERIA
IEC028I 837-08,IFG055 ,CSWCNSA,RACFSTD,SYS00287,971E,SMC001,CSWCNSA.COBOL.DDIO
***
Back to top
View user's profile Send private message
dbzTHEdinosauer

Global Moderator


Joined: 20 Oct 2006
Posts: 6966
Location: porcelain throne

PostPosted: Tue Nov 03, 2009 11:18 pm
Reply with quote

the third variable in you input screen is invalid
Back to top
View user's profile Send private message
Robert Sample

Global Moderator


Joined: 06 Jun 2008
Posts: 8696
Location: Dubuque, Iowa, USA

PostPosted: Tue Nov 03, 2009 11:42 pm
Reply with quote

How did you define the DDIO? The x37 is usually a space problem but since you have a lot of other things in your post, it's hard to be sure.
Back to top
View user's profile Send private message
ibmmainframe1

New User


Joined: 26 Jul 2005
Posts: 64
Location: India

PostPosted: Wed Nov 04, 2009 3:10 pm
Reply with quote

Pls find the steps that I followed to create a file and let me know if I made any mistake.

I appreciate your help.
Back to top
View user's profile Send private message
expat

Global Moderator


Joined: 14 Mar 2007
Posts: 8797
Location: Welsh Wales

PostPosted: Wed Nov 04, 2009 3:59 pm
Reply with quote

1) DO NOT post attachments as not every user is permitted to open them, thus reducing the number of people able to help you.

2) SVM4000I is a message issued by the BMC product StopX37 - so maybe you should look at space allocations
Back to top
View user's profile Send private message
Robert Sample

Global Moderator


Joined: 06 Jun 2008
Posts: 8696
Location: Dubuque, Iowa, USA

PostPosted: Wed Nov 04, 2009 4:21 pm
Reply with quote

You need to contact your site support group for assistance. I suspect the space you are attempting to give the DDIO file is not available due to site constraints. Only your site support group can assist you in getting the DDIO file set up correctly.
Back to top
View user's profile Send private message
ibmmainframe1

New User


Joined: 26 Jul 2005
Posts: 64
Location: India

PostPosted: Wed Nov 04, 2009 5:01 pm
Reply with quote

Thank you All. I will check here with system team. Meantime if there is anything else I need to do pls post.
Back to top
View user's profile Send private message
ibmmainframe1

New User


Joined: 26 Jul 2005
Posts: 64
Location: India

PostPosted: Wed Nov 04, 2009 7:58 pm
Reply with quote

I was trying to create the ddio using the utility CWDDSUTL, but the job is failing with S213.

SYSTEM COMPLETION CODE=213 REASON CODE=000000C8
TIME=08.57.29 SEQ=21849 CPU=0000 ASID=00BB
PSW AT TIME OF ERROR 075C1000 80E66226 ILC 2 INTC 0D
NO ACTIVE MODULE FOUND
NAME=UNKNOWN
DATA AT PSW 00E66220 - 41003B92 0A0D41F0 38BE56F0
AR/GR 0: 00CDCAB0/00E66504 1: 00000000/A4213000
2: 00000000/00007CB8 3: 00000000/00E65972
4: 00000000/007B9410 5: 00000000/007B97A4
6: 00000000/007B974C 7: 00000000/007B97A4
8: 00000000/007B976C 9: 00000000/007BACA8
A: 00000000/00E67414 B: 00000000/00E68B1C
C: 00000000/80E68BFC D: 00000000/007B96D0
E: 00000000/80E65AAA F: 00000000/000000C8
END OF SYMPTOM DUMP

using the job:
//UTILITY EXEC PGM=CWDDSUTL,REGION=4M,COND=(8,LT)
//*STEPLIB DD DISP=SHR,DSN=SYS5.XPEDITER.LINKLIB NOT VALID ANYMORE
//ABNLDFIL DD DISP=SHR,DSN=CSWCNSA.XPED.DDIO
//ABNLREPT DD SYSOUT=*
//ABNLTERM DD SYSOUT=*
//ABNLPARM DD *
FORMAT TYPE=SOURCE,GC=8,EXTENTS=460,AD=DUPS,RC=100,BLK=4096
DIRX
/*
//
//* EXTENTS=460 IS MAXIMUM EXTENTS NUMBER, 256 IS ABOUT AVERAGE
Back to top
View user's profile Send private message
dbzTHEdinosauer

Global Moderator


Joined: 20 Oct 2006
Posts: 6966
Location: porcelain throne

PostPosted: Wed Nov 04, 2009 8:14 pm
Reply with quote

ok, responding to your next post.

first, I would try to generate a DDIO with much smaller allocations.

if that does not work, then

I would then get with your support group, as they tailor the jcl to be generated for the creation of DDIO files.
Back to top
View user's profile Send private message
ibmmainframe1

New User


Joined: 26 Jul 2005
Posts: 64
Location: India

PostPosted: Wed Nov 04, 2009 8:17 pm
Reply with quote

Hi Dick,

I use the same however getting the error which I posted at the top. (first post)
Back to top
View user's profile Send private message
dbzTHEdinosauer

Global Moderator


Joined: 20 Oct 2006
Posts: 6966
Location: porcelain throne

PostPosted: Wed Nov 04, 2009 8:22 pm
Reply with quote

ibmmainframe1,
see my previous post, I have edited it and changed my remarks.
Back to top
View user's profile Send private message
Robert Sample

Global Moderator


Joined: 06 Jun 2008
Posts: 8696
Location: Dubuque, Iowa, USA

PostPosted: Wed Nov 04, 2009 8:35 pm
Reply with quote

There is definitely something wrong with the way you are building your DDIO. A 213-C8 means
Quote:
C8
An attempt was made to open a compressed data set for update. The update option is not supported for compressed data sets.
I use VSAM DDIO files so I can't really say much about the sequential DDIO files. However, I did find the Ccmpuware recommended batch job to allocate a new sequential DDIO file:
Code:
//**********************************************************************
//*                                                                    *
//*   CXALLDS -  JCL TO ALLOCATE THE COMPUWARE PROPRIETARY             *
//*              DATA ACCESS METHOD (DDIO) FILES.     (SEQUENTIAL)     *
//*                                                                    *
//*   ***  THIS JCL CAN BE USED TO ALLOCATE ALL SUPPORTED SEQ.  ***    *
//*   ***  DDIO FILE TYPES                                      ***    *
//*                                                                    *
//*  NOTE:  SECONDARY EXTENTS MUST NOT BE USED.                        *
//*                                                                    *
//**********************************************************************
//*     CREATE SEQUENTIAL REPORT, SOURCE LISTING, AND OTHER            *
//*                     DDIO FILES.                                    *
//**********************************************************************
//*
//CXALLDS  PROC  VOLSER=VVVVVV,                     <--- SUPPLY VOLSER
//         CXDDIO='COMPWARE.CX.DDIO',               <--- CHECK DSN
//         BLKSIZE=27998,                           <--- BLKSIZE
//         BLKNO=4500,                              <--- NUMBER OF BLKS
//         DUNIT='SYSDA'                            <--- DASD UNIT
//*
//STEP01   EXEC PGM=IEFBR14
//CXDDIO   DD DSN=&CXDDIO,
//            DISP=(,CATLG),
//            UNIT=&DUNIT,
//            SPACE=(&BLKSIZE,(&BLKNO)),
//            VOL=SER=&VOLSER
//            PEND
//JCLALLOC EXEC CXALLDS
Back to top
View user's profile Send private message
ibmmainframe1

New User


Joined: 26 Jul 2005
Posts: 64
Location: India

PostPosted: Thu Nov 05, 2009 3:45 pm
Reply with quote

Hi Robert,

I created the DDIO file using your JCL, but when I compile with xped 'y' in changeman the job is failing with the following error. pls advise.

PCOPTN028-I COMPUWARE COBOL PROCESSOR - RELEASE 08.06.00 (PTF CXN0139)
PCOPTN027-I COBOL(OUTPUT(NOPRINT, NODDIO))
PCOPTN027-I DDIO(OUTPUT(FIND))
PCOPTN027-I LANGPARM(XREF, MAP)
PCOPTN027-I LANGUAGE(COBOL/370)
PCOPTN027-I PRINT(OUTPUT(LIST, XREF, MAP))
PCOPTN027-I PROCESSOR(OUTPUT(PRINT, DDIO))
PCOPTN027-I AWO, NOC(E), LIB, MAP, BUF(128K), CP(37), DATA(31), OFF, VBREF, X
PCOPTN271-S CWPDDIO IS NOT A SOURCE DDIO FILE OR DATABASE.
PCFLEX095-W
PCFLEX095-W "BUFSIZE" VALUE DECREASED BECAUSE IT EXCEEDED DATA MANAGEMENT MAX
PCFLEX095-W
PCOPTN041-I PROCESSED ON 11/05/2009 AT 05:00:21
Back to top
View user's profile Send private message
dbzTHEdinosauer

Global Moderator


Joined: 20 Oct 2006
Posts: 6966
Location: porcelain throne

PostPosted: Thu Nov 05, 2009 3:58 pm
Reply with quote

Quote:
PCOPTN271-S CWPDDIO IS NOT A SOURCE DDIO FILE OR DATABASE.


I think you will find that the qsam that you created
does not support xpeditor use of a ddio file while debugging.

the qsam file is probably only a methodology to move, print members.

I believe that you will have to create a VSAM DDIO file,
which I did not see until the 8 or 10th post.
and was not sure if a new release of xpeditor supported the qsam for debugging.

the error code that you received indicates that qsam is not what you need.
Back to top
View user's profile Send private message
ibmmainframe1

New User


Joined: 26 Jul 2005
Posts: 64
Location: India

PostPosted: Thu Nov 05, 2009 5:02 pm
Reply with quote

Hi Dick,

Can I use the same JCL to create the VSAM file using IDCAMS something like that...
Back to top
View user's profile Send private message
dbzTHEdinosauer

Global Moderator


Joined: 20 Oct 2006
Posts: 6966
Location: porcelain throne

PostPosted: Thu Nov 05, 2009 5:18 pm
Reply with quote

again,
go back to the utilities option of the ISPF xpeditor screens,
and use the screen to generate jcl to create a job that creates a vsam ddio file.
Back to top
View user's profile Send private message
Robert Sample

Global Moderator


Joined: 06 Jun 2008
Posts: 8696
Location: Dubuque, Iowa, USA

PostPosted: Thu Nov 05, 2009 5:50 pm
Reply with quote

Whether the DDIO is VSAM or sequential, this message
Quote:
PCOPTN271-S CWPDDIO IS NOT A SOURCE DDIO FILE OR DATABASE.
tells me you need to contact your site support group for assistance. Compuware has started linking DDIO files into a report and source database, and the message implies that your file needs to be so linked. The procedure to do this will be known to your site support group and the database may well have restricted access that would prevent you from doing this on your own.
Back to top
View user's profile Send private message
ibmmainframe1

New User


Joined: 26 Jul 2005
Posts: 64
Location: India

PostPosted: Thu Nov 05, 2009 7:23 pm
Reply with quote

Thanks Robert and Dick for your continued support.
Back to top
View user's profile Send private message
ibmmainframe1

New User


Joined: 26 Jul 2005
Posts: 64
Location: India

PostPosted: Fri Nov 06, 2009 9:25 pm
Reply with quote

Hi All,

I have created a shared Directory DDIO file and when i run the job I am getting following error..

Code:
 PCOPTN041-I  DDIO                                                             
 PCOPTN041-I  OUTPUT ( NOLIST, NOPMAP, NOOFFSET, NOCLIST, NOXREF, NODMAP, NOMAP
 PCOPTN041-I  ( PROGRAM-NAME( ) )                                             
 PCOPTN041-I                                                                   
 PCOPTN041-I  PRINT                                                           
 PCOPTN041-I  OUTPUT ( SOURCE, LIST, PMAP, OFFSET, CLIST, XREF, DMAP, MAP )   
 PCOPTN041-I                                                                   
 PCSIO 054-S  NO DATABASE FILES IN SELECTION LIST .                           
 PCSIO 006-S  OUTPUT FILE CWPDDIO OPENMEM ERROR, RETURN CODE=48-046.           
 PCDRVR053-I  ** ERRORS PROCESSING LISTING CS001478 DATED 11/06/2009 AT 08:57:4


This my DDIO info. Pls advise..

Code:
SHARED DIRECTORY INFORMATION                                         
AM(ACCESS METHOD) ............... VSAM                               
BLKSIZE ......................... 18425                               
OTHER INFORMATION                                                     
  DIRECTORY FORMATTED BY DDIO ... 8.6.0                               
  REQUIRES MINIMUM DDIO RELEASE . 7.0.0                               
  TOTAL BLOCKS IN SHARED DIR .... 200                                 
  USED BLOCKS ................... 19(10%)                             
  NUMBER OF EXTENTS ............. 1                                   
                                                                     
                                                                     
DBMODEL INFORMATION:                                                 
 DBMODEL ........................ NOT FOUND OR HAS NOT BEEN DEFINED   
                                                                     
NUMBER OF ATTACHED DATABASE(S)................ 0                     
Back to top
View user's profile Send private message
Robert Sample

Global Moderator


Joined: 06 Jun 2008
Posts: 8696
Location: Dubuque, Iowa, USA

PostPosted: Fri Nov 06, 2009 9:47 pm
Reply with quote

It does not appear your DDIO is defined correctly. See the Compuware manual Enterprise Common Components User/Reference Guide MVS for details on setting up a DBMODEL. It's been quite a while since I've had to set up any of this, so my memory does not recall the exact steps. I think the process was to allocate the DDIO, format it using the utility, and then link it to a database. But it's fuzzy so I could be forgetting a step or two.

If you have not contacted your site support group, I strongly recommend you do so since some of the Compuware definitions depend upon what is already defined at your site.
Back to top
View user's profile Send private message
ibmmainframe1

New User


Joined: 26 Jul 2005
Posts: 64
Location: India

PostPosted: Tue Nov 10, 2009 9:53 pm
Reply with quote

Hi All,

I created DDIO using someone's else in Fileaid.

All these days I was trying to allocate new file or xped to create and that was failing.

Today in Fileaid utilities copy option used to copy someone's into mine and it worked.

Thanks all for your help.
Back to top
View user's profile Send private message
dick scherrer

Moderator Emeritus


Joined: 23 Nov 2006
Posts: 19244
Location: Inside the Matrix

PostPosted: Tue Nov 10, 2009 10:32 pm
Reply with quote

Good to hear it is working - thank you for the update icon_smile.gif

d
Back to top
View user's profile Send private message
David Ashlock

New User


Joined: 02 Nov 2011
Posts: 2
Location: USA

PostPosted: Tue Apr 02, 2013 1:26 am
Reply with quote

Our experience with the PCOPTN271-S CWPDDIO IS NOT A SOURCE DDIO FILE OR DATABASE. was due to a security issue and not based on the definition of the file. The user did not have UPDATE CONTROL or ALL and was not allowed to write to dataset.
Back to top
View user's profile Send private message
Gary McDowell

Active User


Joined: 15 Oct 2012
Posts: 139
Location: USA

PostPosted: Tue Apr 02, 2013 3:36 am
Reply with quote

David Ashlock wrote:
Our experience with the PCOPTN271-S CWPDDIO IS NOT A SOURCE DDIO FILE OR DATABASE. was due to a security issue and not based on the definition of the file. The user did not have UPDATE CONTROL or ALL and was not allowed to write to dataset.

Welcome David.
As an FYI the original post of this thread was Tue Nov 03, 2009 1:00 pm.
Back to top
View user's profile Send private message
David Ashlock

New User


Joined: 02 Nov 2011
Posts: 2
Location: USA

PostPosted: Tue Apr 02, 2013 3:38 am
Reply with quote

I know, but I just came across this issue for us and that was our issue, same message, different problem.
Back to top
View user's profile Send private message
View previous topic :: :: View next topic  
Post new topic   Reply to topic View Bookmarks
All times are GMT + 6 Hours
Forum Index -> Compuware & Other Tools

 


Similar Topics
Topic Forum Replies
No new posts Error to read log with rexx CLIST & REXX 11
No new posts Error when install DB2 DB2 2
No new posts CLIST - Virtual storage allocation error CLIST & REXX 5
No new posts Error while running web tool kit REXX... CLIST & REXX 5
No new posts Getting Error while trying to establi... DB2 3
Search our Forums:

Back to Top