Hi,
I am getting an error as in a JCL
"CONTROL CARD MEMBER IS ISPF PACKED FORMAT".
Any idea why such an error is coming up?
Thanks. |
|
Back to top |
|
|
Robert Sample
Global Moderator
Joined: 06 Jun 2008 Posts: 8696 Location: Dubuque, Iowa, USA
|
|
|
|
Probably because the control card member specified has been packed under ISPF. |
|
Back to top |
|
|
rosmi joseph
New User
Joined: 17 Sep 2007 Posts: 68 Location: Kochi
|
|
|
|
Hi Thanks.
Any idea how to rectify this error? |
|
Back to top |
|
|
Robert Sample
Global Moderator
Joined: 06 Jun 2008 Posts: 8696 Location: Dubuque, Iowa, USA
|
|
|
|
Go into ISPF, turn packing off, then save the member. |
|
Back to top |
|
|
ofer71
Global Moderator
Joined: 27 Dec 2005 Posts: 2358 Location: Israel
|
|
|
|
You can add a preliminary step: Batch ISPF that issues an EDIT service for that member, with macro. Then create a macro with the PACK OFF command and END.