View previous topic :: View next topic
|
Author |
Message |
cicsknow
New User
Joined: 11 Mar 2009 Posts: 28 Location: India
|
|
|
|
Hi,
We are gettig S047 abend during restarting a CICS tool. I have found information for this abend and come to know that, its due to APF authority.
But i have check all STEPLIB library of that CICS tool already listed as APF authorize in MVS image.
Can any have idea on it....
Thanks in Advance for your reply. |
|
Back to top |
|
|
Robert Sample
Global Moderator
Joined: 06 Jun 2008 Posts: 8696 Location: Dubuque, Iowa, USA
|
|
|
|
Could a program be getting pulled in from the Linklist? Linklist programs can be authorized or not so executing a program from an unauthorized Linklist library could cause the S047. Consult your site support group for help in determining the root of the problem -- they can set a SLIP trip and have you restart the tool to provide data about the problem program. |
|
Back to top |
|
|
cicsknow
New User
Joined: 11 Mar 2009 Posts: 28 Location: India
|
|
|
|
Thanks Robert for your reply, Actually, we missed one module to include in APF library. |
|
Back to top |
|
|
Robert Sample
Global Moderator
Joined: 06 Jun 2008 Posts: 8696 Location: Dubuque, Iowa, USA
|
|
|
|
LOL that'll do it. Glad to hear you've got it resolved. |
|
Back to top |
|
|
|