View previous topic :: View next topic
|
Author |
Message |
anilkumar123
New User
Joined: 08 Oct 2008 Posts: 2 Location: hyd
|
|
|
|
i tried using (1,3,ZD,TO=PD,LENGHT=2) its converting to PD but the hex values are not matching , can any 1 suggest me upon this??? |
|
Back to top |
|
|
dick scherrer
Moderator Emeritus
Joined: 23 Nov 2006 Posts: 19244 Location: Inside the Matrix
|
|
|
|
Hello,
Quote: |
can any 1 suggest me upon this |
I suggest you post some real input data and the output data you are getting that you do not want. Also post the data you want for output.
You only need to post all 3 sets of data for a few records - not a large volume. |
|
Back to top |
|
|
Frank Yaeger
DFSORT Developer
Joined: 15 Feb 2005 Posts: 7129 Location: San Jose, CA
|
|
|
|
anilkumar123,
I assume you actually had "LENGTH" and not "LENGHT" as shown.
Show an example of the 3-byte ZD input value in hex and the resulting 2-byte PD output value in hex for a case where they "don't match". Indicate what you expect for output in hex. |
|