View previous topic :: View next topic
|
Author |
Message |
ar_karthick
New User
Joined: 17 Dec 2007 Posts: 4 Location: India
|
|
|
|
Hi All,
Am getting the following error in my CICS region log.
ERROR:
DFHZC6907 I 06/07/2008 12:05:09 CIC18THT AUTOINSTALL STARTING FOR NETNAME SI8O4018. NETWORK QUALIFIED NAME IS CHEMNET.V0SGB408.
DFHZC6987 W 06/07/2008 12:05:09 CIC18THT AUTOINSTALL BEST FAILURE FOR NETNAME SI8O4018 WAS MODEL DFHLU2E3.
CINIT BIND: 010303B1 90308000 07888887 00028000 00000018 5018507F 000008C3 C9C3F0F6
C5C1E300 050015DB 9628
MODEL BIND: 010303B1 B0308000 0087F800 00028000 00000018 5020507F
MISMATCH BITS: 00000000 00000000 00000000 00000000 00000000 0038
DFHZC2411 E 06/07/2008 12:05:11 CIC18THT DUMY CSNE SI8O4018 ATTEMPTED INVALID LOGON. ((7) MODULE NAME: DFHZATA)
NQNAME DUMY,CSNE,12:05:11,CHEMNET SI8O4018
Please let me know how to resolve this problem. |
|
Back to top |
|
|
Srinivasa Rao
New User
Joined: 21 Jun 2005 Posts: 75
|
|
|
|
Hi,
You will get this error message when trying to connect to unauthorized terminal.
So contact security team to provide access.
If you find out a solution and my above solution is wrong please let us know. |
|
Back to top |
|
|
josephvincentd Warnings : 1 New User
Joined: 19 May 2005 Posts: 15
|
|
|
|
If it is not a security issue
It almost appears that your Auto Install program is setup to only
autoinstall devices if the BIND that CICS receives matches a model type
term exactly. |
|