View previous topic :: View next topic
|
Author |
Message |
giri_knair
New User
Joined: 01 Feb 2006 Posts: 2
|
|
|
|
IEF374I STEP/DMSCHAR /STOP 2008156.1027 CPU 0MIN 00.06SEC SRB 0MIN 00.
IEF344I AWBKR#36 DELTB DD1 - ALLOCATION FAILED DUE TO DATA FACILITY SYSTEM ER
IGD17102I CATALOG ERROR IN DEFINING NONVSAM DATA SET
WDA.VND.AWBKR.D080603.T222459.TDR
RETURN CODE IS 20 REASON CODE IS 0 IGG0CLEG
IGD306I UNEXPECTED ERROR DURING IGG0CLEG PROCESSING
RETURN CODE 20 REASON CODE 0
THE MODULE THAT DETECTED THE ERROR IS IGDVTSCU
SMS MODULE TRACE BACK - VTSCU VTSCT VTSCR SSIRT |
|
Back to top |
|
|
Manuneedhi K
Active User
Joined: 07 May 2008 Posts: 115 Location: Chennai
|
|
|
|
A return code of 20 suggests the below in quick reference (QW)
Explanation: The volume entry being removed from an
catalog entry during ALTER REMOVEVOLUMES processing
cannot be found in the catalog record.
Programmer Response: Verify that the volume serial
numbers specified actually exist in the catalog entry
for the data set being altered.
IMO trying to re-run the job after sometime might resolve this . |
|
Back to top |
|
|
giri_knair
New User
Joined: 01 Feb 2006 Posts: 2
|
|
|
|
IEF344I PART2#WL COPY1A SLUGREP SYSUT2 - ALLOCATION FAILED DUE TO DATA FACILITY SYSTEM ERROR
IGD17102I CATALOG ERROR IN DEFINING NONVSAM DATA SET
WDA.F7871555.VND.CQSTATES.D080604.T074457
RETURN CODE IS 20 REASON CODE IS 0 IGG0CLEG
IGD306I UNEXPECTED ERROR DURING IGG0CLEG PROCESSING
RETURN CODE 20 REASON CODE 0
THE MODULE THAT DETECTED THE ERROR IS IGDVTSCU
SMS MODULE TRACE BACK - VTSCU VTSCT VTSCR SSIRT
SYMPTOM RECORD CREATED, PROBLEM ID IS IGD00061
IEF272I PART2#WL COPY1A SLUGREP - STEP WAS NOT EXECUTED.
IEF285I DOGSNUF.PART2#WL.JOB02527.D0000121.? SYSOUT
*****************************************************************************************************************
reson was : the file name assosiated with it.
suppose the file name is :xxx.aa.bx
there will be volumes associated with XXX which were exhausted and so resolution for this was
1. Reorganize the xxx catalog
2. Add some volumes to XXX spool. |
|
Back to top |
|
|
expat
Global Moderator
Joined: 14 Mar 2007 Posts: 8797 Location: Welsh Wales
|
|
|
|
Having chased the error messages through, it looks as though your user catalog has run out of space, and there is insufficient space on the volume for further expansion, or that the catalog has reached its full number of allowed extents.
Quote: |
+------------------------------------------------------------------------+
| RETURN CODE 20 |
| |
| Explanation: There is insufficient space in the catalog to perform the |
| requested update or addition. |
+------------------------------------------------------------------------+
Reason Code Description
0 Explanation: The catalog is full. It is impossible to
obtain another extent, because there is no more space
on the volume in which the catalog resides, or the
maximum number of extents has been reached.
Programmer Response: Scratch unneeded data sets from
the volume. Delete all unnecessary entries from the
catalog. The catalog may need to be reallocated and
rebuilt if these steps do not resolve the space
shortage.
|
|
|
Back to top |
|
|
|