hi,

In a check point call in a batch IMS program, im getting status codes
AL for IO PCB and status code GE for check point pcb.

Please suggest how to rectify the error.. Please specify if further details are required for problem determination.
Back to top
View user's profile Send private message
Sasi Kiran Patha
Warnings : 2

New User


Joined: 19 Nov 2006
Posts: 73
Location: Hyederabad

PostPosted: Fri Nov 23, 2007 4:52 pm
Reply with quote

A small correction, sorry, its first restart call in the begining of the program execution.

In a restart call in a batch IMS program, im getting status codes
AL for IO PCB and status code GE for check point pcb.

Please suggest how to rectify the error.. Please specify if further details are required for problem determination.
Back to top
View user's profile Send private message
Bitneuker

CICS Moderator


Joined: 07 Nov 2005
Posts: 1104
Location: The Netherlands at Hole 19

PostPosted: Mon Nov 26, 2007 4:36 pm
Reply with quote

Sasi Kiran Patha wrote:
A small correction, sorry, its first restart call in the begining of the program execution.

In a restart call in a batch IMS program, im getting status codes
AL for IO PCB and status code GE for check point pcb.

Please suggest how to rectify the error.. Please specify if further details are required for problem determination.


A batch IMS program cannot issue calls on the IO-PCB; click

As for the GE click.

Looks like a mix-up; sure this is a batch program or is it a nonmessage driven BMP? The AL tells you issue calls against the IO-PCB so probably you should run it as a message driven BMP.
Back to top
View user's profile Send private message
Sasi Kiran Patha
Warnings : 2

New User


Joined: 19 Nov 2006
Posts: 73
Location: Hyederabad

PostPosted: Wed Dec 12, 2007 6:00 pm
Reply with quote

IO PCB is valid in a batch DLI program for check point restart call.

The error was because the PSB definition was not properly set in the region's checkpoint restart database.

Thank you,
Sasi Kiran Patha.
Back to top
View user's profile Send private message
View previous topic :: :: View next topic  
Post new topic   Reply to topic View Bookmarks
All times are GMT + 6 Hours
Forum Index -> IMS DB/DC

 


Similar Topics
Topic Forum Replies
No new posts ISAM and abend S03B JCL & VSAM 10
No new posts Return codes-Normal & Abnormal te... JCL & VSAM 7
No new posts Error while running web tool kit REXX... CLIST & REXX 5
No new posts Call program, directly from panel CLIST & REXX 9
No new posts Abend S0C4 11 (Page Translation Excep... PL/I & Assembler 16
Search our Forums:

Back to Top