Author Message
gowrishankari_s

New User


Joined: 15 Feb 2007
Posts: 4
Location: hyderabad

PostPosted: Fri Sep 21, 2007 3:19 pm    Post subject: Command to view the Max-CC view in Spool
Reply with quote

Hi all,

What is the command to view the Max-cc number next to the job itself. Usually we need to do a PF8 for that.

Thanks in advance
Gowri
Back to top
View user's profile Send private message

murmohk1

Senior Member


Joined: 29 Jun 2006
Posts: 1439
Location: Bangalore,India

PostPosted: Fri Sep 21, 2007 3:27 pm    Post subject:
Reply with quote

Gowri,

Quote:
What is the command to view the Max-cc number next to the job
itself. Usually we need to do a PF8 for that.

Use ARR ?. Change the column order.
Back to top
View user's profile Send private message
Aaru

Senior Member


Joined: 03 Jul 2007
Posts: 1288
Location: Chennai, India

PostPosted: Fri Sep 21, 2007 4:38 pm    Post subject: Reply to: Max-CC view in Spool
Reply with quote

murali,

Quote:
Use ARR ?. Change the column order.


To get the Max-Rc i sually do PF11 in the spool to get the RC value. How to change the column order? Please advise.
Back to top
View user's profile Send private message
twissi

Active User


Joined: 01 Aug 2005
Posts: 105
Location: Somerset, NJ

PostPosted: Fri Sep 21, 2007 5:06 pm    Post subject:
Reply with quote

Gowri, Aaru,

I'll explain Murali's suggestion. ARR ? is used to arrange the spool display fields.

Go to spool and type ARR? as shown below:
Code:
COMMAND INPUT ===> ARR ? 

and ARRANGE window pops up as shown below:

Code:
     Column              Width   Description   
      JobID                   8                 
      Owner                   8                 
      Prty                    4                 
      Pos                     5                 
      Max-RC                 10   Delayed access
      Queue                  10                 
      C                       1                 
      SAff                    5                 
      ASys                    4                 
      Status                 17                 
      PrtDest                18                 


Use '/' or '//' to move a single filed or a group of fields respectively and move it(them) 'B' Before or 'A' After a field.

Hope this helps,
Cheers, T.
Back to top
View user's profile Send private message
Aaru

Senior Member


Joined: 03 Jul 2007
Posts: 1288
Location: Chennai, India

PostPosted: Fri Sep 21, 2007 5:18 pm    Post subject: Reply to: Max-CC view in Spool
Reply with quote

It worked and i was able to move the column. Thanks a lot twissi.
Back to top
View user's profile Send private message
twissi

Active User


Joined: 01 Aug 2005
Posts: 105
Location: Somerset, NJ

PostPosted: Fri Sep 21, 2007 5:44 pm    Post subject:
Reply with quote

I knew it would..! icon_lol.gif
Back to top
View user's profile Send private message
Anuj Dhawan

Senior Member


Joined: 22 Apr 2006
Posts: 6258
Location: Mumbai, India

PostPosted: Fri Sep 21, 2007 6:26 pm    Post subject:
Reply with quote

Hi,

I used the above suggested option
Quote:
ARR ?
& got the following
Code:
                           Arrange           Row 1 to 11 of 19
Command ===>                                                 
                                                             
Select a column or block with / or // then type A (after) or 
B (before) to move. Special function keys:                   
F5/17=Refresh list  F11/23=Clear input  F6/18=Default order   
                                                             
     Column              Width   Description                 
     TYP                     3                               
     JNUM                    5                               
     JC                      2                               
     JP                      2                               
     QUE                     3                               
     SAFF                    4                               
     ASYS                    4                               
     STATUS                  6                               
     ROOM                    5   Delayed access               
     PROGRAMMER NAME        21   Delayed access               
     ACCT                    5   Delayed access               
     ISYS                    4   Delayed access
     RDR TIME                8   Delayed access
     RDR DT                 10   Delayed access
     ESYS                    4   Delayed access
     STA TIME                8   Delayed access
     STA DT                 10   Delayed access
     END TIME                8   Delayed access
     END DT                 10   Delayed access


but didn't get any column for
Code:
Max-RC                 10   Delayed access


why so, is it site specific ?
Back to top
View user's profile Send private message
twissi

Active User


Joined: 01 Aug 2005
Posts: 105
Location: Somerset, NJ

PostPosted: Fri Sep 21, 2007 7:05 pm    Post subject:
Reply with quote

Anuj,

The one I gave was for SDSF;ST.

Twissi.
Back to top
View user's profile Send private message
Anuj Dhawan

Senior Member


Joined: 22 Apr 2006
Posts: 6258
Location: Mumbai, India

PostPosted: Wed Sep 26, 2007 4:03 pm    Post subject:
Reply with quote

twissi wrote:
The one I gave was for SDSF;ST.

Hi twissi,

I've also showed the results of SDSF/S.ST, why do they defer icon_confused.gif
Back to top
View user's profile Send private message
twissi

Active User


Joined: 01 Aug 2005
Posts: 105
Location: Somerset, NJ

PostPosted: Thu Sep 27, 2007 3:21 pm    Post subject:
Reply with quote

Hi Anuj,

Maybe they're site specific, as you guessed earlier..!

T.
Back to top
View user's profile Send private message
Anuj Dhawan

Senior Member


Joined: 22 Apr 2006
Posts: 6258
Location: Mumbai, India

PostPosted: Thu Sep 27, 2007 4:04 pm    Post subject:
Reply with quote

Hi,

May be. Looking for some Moderators/ Senior Member's reply, hopefully someone from them can help.
Back to top
View user's profile Send private message
murmohk1

Senior Member


Joined: 29 Jun 2006
Posts: 1439
Location: Bangalore,India

PostPosted: Thu Sep 27, 2007 4:27 pm    Post subject:
Reply with quote

Anuj,

Quote:
May be. Looking for some Moderators/ Senior Member's reply,
hopefully someone from them can help.

How do you see RC after the job completion?
Back to top
View user's profile Send private message
Anuj Dhawan

Senior Member


Joined: 22 Apr 2006
Posts: 6258
Location: Mumbai, India

PostPosted: Thu Sep 27, 2007 6:24 pm    Post subject:
Reply with quote

I look in JESMSGLG.
Back to top
View user's profile Send private message
murmohk1

Senior Member


Joined: 29 Jun 2006
Posts: 1439
Location: Bangalore,India

PostPosted: Thu Sep 27, 2007 7:55 pm    Post subject:
Reply with quote

Anuj,

Quote:
I look in JESMSGLG.

Assuming you need to check the RC of multiple jobs (say 100 jobs), you need to repeat this for every job rite?????

Press F11 and see you have any column which shows MAXCC.
Back to top
View user's profile Send private message
twissi

Active User


Joined: 01 Aug 2005
Posts: 105
Location: Somerset, NJ

PostPosted: Thu Sep 27, 2007 8:05 pm    Post subject:
Reply with quote

murmohk1 wrote:

Press F11 and see you have any column which shows MAXCC.


MAXCC won't be seen if you don't have it in the list for ARR ?, when you press PF11.
Back to top
View user's profile Send private message
murmohk1

Senior Member


Joined: 29 Jun 2006
Posts: 1439
Location: Bangalore,India

PostPosted: Thu Sep 27, 2007 8:20 pm    Post subject:
Reply with quote

twissi,
Quote:
MAXCC won't be seen if you don't have it in the list for ARR ?, when you press PF11.

Since the panel what Anuj has posted is a tailored one, I expect they might have RENAMED the maxcc column (long shot).
Back to top
View user's profile Send private message
Anuj Dhawan

Senior Member


Joined: 22 Apr 2006
Posts: 6258
Location: Mumbai, India

PostPosted: Thu Oct 04, 2007 6:39 pm    Post subject:
Reply with quote

murmohk1 wrote:
Since the panel what Anuj has posted is a tailored one, I expect they might have RENAMED the maxcc column (long shot).

Hi Murali,

Why do you think that the panel posted by me is a tailored one?
Back to top
View user's profile Send private message
murmohk1

Senior Member


Joined: 29 Jun 2006
Posts: 1439
Location: Bangalore,India

PostPosted: Thu Oct 04, 2007 6:43 pm    Post subject:
Reply with quote

Anuj,

Quote:
Why do you think that the panel posted by me is a tailored one?

Because the normal IBM supplied panel shows MAXCC column.
Back to top
View user's profile Send private message
Anuj Dhawan

Senior Member


Joined: 22 Apr 2006
Posts: 6258
Location: Mumbai, India

PostPosted: Thu Oct 04, 2007 7:29 pm    Post subject:
Reply with quote

Murali,

I did this to get the panel shown is my post:

Code:
START/S.ST/ ARR ?


What came there, I post it here. If the panel is a tailored one then I think, I need to get in touch with system guys, but I doubt it they've done this. What benefit will they get by hiding/changing the MAXCC column ?
Back to top
View user's profile Send private message
khamarutheen

Active Member


Joined: 23 Aug 2005
Posts: 680
Location: NJ

PostPosted: Thu Oct 04, 2007 7:58 pm    Post subject:
Reply with quote

Hi,

I am confused here .. I am having 3 jobs i wanna to see the maxcc of 2nd job will arr ? will do??? how do i assure that it is showing for job 2????
Back to top
View user's profile Send private message
View previous topic :: :: View next topic  
Post new topic   Reply to topic    IBMMAINFRAMES.com Support Forums -> TSO/ISPF All times are GMT + 6 Hours
Goto page 1, 2  Next
Page 1 of 2

 

Search our Forum:

Similar Topics
Topic Author Forum Replies Posted
No new posts What is the command to check MODE of ... rohanthengal CLIST & REXX 6 Fri Nov 18, 2016 1:48 pm
No new posts SDSF Command Avtrix CLIST & REXX 4 Fri Sep 30, 2016 11:13 am
No new posts How to find a CICS resource used in C... Arunkumar Chandrasekaran CICS 8 Thu Sep 29, 2016 1:45 pm
No new posts COMPARE command sivatechdrive TSO/ISPF 7 Fri Sep 16, 2016 4:31 pm
No new posts I am unable to use SWAPBAR ON command... mrsidhu12 TSO/ISPF 3 Thu Sep 01, 2016 1:10 pm


Facebook
Back to Top
 
Mainframe Wiki | Forum Rules | Bookmarks | Subscriptions | FAQ | Tutorials | Contact Us