View previous topic :: View next topic
|
Author |
Message |
Libu Thomas
New User
Joined: 01 Jan 2007 Posts: 6 Location: India
|
|
|
|
Hi,
I would like to know whether we should declare a PSB for an IMS DC program. I am using DB2 and no IMS DB. Its an MPP. |
|
Back to top |
|
|
enrico-sorichetti
Superior Member
Joined: 14 Mar 2007 Posts: 10872 Location: italy
|
|
|
|
Unless something has changed You need an I/O pcb to read/write from/to the terminal
so I guess that a PSB is needed
regards
e.s |
|
Back to top |
|
|
Devzee
Active Member
Joined: 20 Jan 2007 Posts: 684 Location: Hollywood
|
|
|
|
For IMS programs you definitely need PSB.
In IMS DB Batch program you need Database PSB
In IMS DC Online program you need atleast Online PSB |
|
Back to top |
|
|
Libu Thomas
New User
Joined: 01 Jan 2007 Posts: 6 Location: India
|
|
|
|
Thanks... |
|
Back to top |
|
|
Karthi-acp
New User
Joined: 21 Apr 2007 Posts: 5 Location: India
|
|
|
|
Please find a sample PSB for IMS DC program
PRINT NOGEN
PCB TYPE=TP,MODIFY=YES,EXPRESS=YES
PSBGEN LANG=COBOL,CMPAT=YES,PSBNAME=APSMF100
END |
|
Back to top |
|
|
|