HI,
Can any one provide me clue on how to do forced terminate use defined DB2 UTILITIES ??
Normaly this utility can be terminated by the user who submited the job, but that job abended, it was his responsibility to terminate the utility, but he din't do so. have to do a fire fight !!
Thanks you.
regard
Dharmendra |
|
Back to top |
|
|
vidhyanarayanan
New User
Joined: 23 Dec 2005 Posts: 52
|
|
|
|
Hi,
The utilities u r tellin will be in stopped status..this is the reason for the
abend.u can terminate this only if u hv DBA authority. the user who
submitted the job is not allowed to terminate. |
|
Back to top |
|
|
martin9
Active User
Joined: 01 Mar 2006 Posts: 290 Location: Basel, Switzerland
|
|
|
|
hy dharmendra_kp,
you can terminate any utility with the TERMINATE command in db2...
but therefore you need the authority as mentioned before...